- Browse by Author
Browsing by Author "Iskandar, Mounir"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item The influence of delayed light curing on the polymerization contraction stress and degree of conversion in dual-cured resin luting agents(2010) Iskandar, Mounir; Platt, Jeffrey A., 1958-; Andres, Carl J., 1942; Hovijitra, Suteena, 1944-; Brown, David T.; Levon, John A.The purpose of this study was 1) To determine the impact of eliminating or delaying the photo-activation procedure on the polymerization contraction stress (PCS)and degree of conversion (DC) of a dual-cured resin luting agent, and 2) To determine the amount of delay in photo-initiation of the dual-cured resin cements that can achieve a reduced PCS value with the highest possible DC. The amount of PCS and DC of a dual-cured resin luting agent was determined using a tensometer and ATR spectroscopic technique, respectively. Photo-activation delay in seven tested groups was 0 min, 2 min, 4 min, 6 min, 8 min, 10 min and no photoactivation. Five samples for each group were tested. There were two hypotheses for this study: 1) A significant decrease in the amount of PCS associated with delayed photo-activation, and 2) A significant increase in DC associated with delayed photo-activation.The PCS of the chemical-cure luting agent had significantly lower value than all of the light-cure groups. For the light-cure groups, those with a 4-min delay had higher PCS than those with delays of 0 min, 2 min, 6 min, 8 min, and 10 min. The zero (0)-min and 2-min delay had higher PCS than the 6-min, 8-min, and 10-min delay; and the 6-min delay had higher PCS than the 8-min and 10-min delay. The PCS decreased 0.086 MPa per minute of delay. The DC of the chemical-cure luting agent had significantly lower value than the 2-min, 4-min, 6-min, 8-min, and 10-min delaylight cure. For the light-cure groups, 0-min delay had a lower DC than the 2-min, 4-min, 6-min, 8-min, and 10-min delay; 2-min delay had lower DC than 4-min, 6-min, 8-min, and 10-min delay. The 4-min and 6-min delay had lower DC than the 8-min and 10-min delay; and the 8-min delay had a lower degree of conversion by peak area than the 10- minute delay. The DC increased 0.021 per minute of delay. Extending the stress relief period of the dual-cured luting agents by delaying light activation has a significant impact on PCS and DC values. There was significant decrease in PCS with the delayed light curing of the resin luting agent. Significant increase in DC was noticed when light activation was delayed in the dual-cured resin luting agents.Item Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics(MDPI, 2021-10-27) Labban, Nawaf; Al Amri, Mohammad D.; Alnafaiy, Sarah M.; Alhijji, Saleh M.; Alenizy, Mohammad A.; Iskandar, Mounir; Feitosa, Sabrina; Biomedical Sciences and Comprehensive Care, School of DentistryThe aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM). One hundred and twenty specimens (12 × 14 × 2.5 mm) were prepared using a precision saw. For each material (n = 24), the specimens were allocated into two groups, polished and stained. The specimens of each group were stored (for 7 days) in either citric acid (0.2N) or distilled water. Data for surface gloss (ΔE*SCE-SCI) and roughness (Ra) were evaluated before (baseline) and after simulated toothbrushing. For toothbrushing simulation, a toothpaste slurry containing a toothpaste of 100 relative dentin abrasion (RDA) and 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Data were analyzed using t-test and ANOVA. A p-value of ≤ to 0.05 was considered significant. The highest mean value of surface gloss was identified in CU (stained-water) (4.3 (0.47)) (ΔE*) and EN (stained-acid) (4.3 (1.00)) (ΔE*) specimens, whereas the lowest mean value was shown by SH (stained-acid) (2.04 (0.42)) (ΔE*) samples. The highest mean value of surface roughness was observed in SH (0.40 (0.99)) Ra (stained-acid) whereas the lowest in VM (0.13 (0.039)) Ra (polished- water). A significant difference (p < 0.05) was observed in surface roughness and gloss between the materials with simulated toothbrushing, except in VM and LU, respectively. Therefore, it can be concluded that simulated toothbrushing impacts on surface roughness and gloss, irrespective of the storage medium.Item Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics(The Korean Academy of Prosthodontics, 2021) Labban, Nawaf; Al Amri, Mohammad; Alhijji, Saleh; Alnafaiy, Sarah; Alfouzan, Afnan; Iskandar, Mounir; Feitosa, Sabrina; Biomedical Sciences and Comprehensive Care, School of DentistryPurpose: The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. Materials and methods: Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. Results: The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. Conclusion: The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.