- Browse by Author
Browsing by Author "Hu, Rongrong"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes(PLOS, 2017-05-18) Hu, Rongrong; Wang, Chenkun; Racette, Lyne; Ophthalmology, School of MedicineBACKGROUND: Perimetry is indispensable for the clinical management of glaucoma suspects. Our goal is to compare the performance of standard automated perimetry (SAP) and Matrix frequency-doubling technology (FDT) perimetry in monitoring the development of visual field (VF) defects in glaucoma suspect eyes. METHODS: Longitudinal data of paired SAP and FDT from 221 eyes of 155 glaucoma suspects enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. All eyes had glaucomatous optic neuropathy or ocular hypertension, but normal SAP and FDT results at baseline. The development of glaucomatous VF defects was defined as the presence of a cluster of ≥ 3 (less conservative) or ≥ 4 (more conservative) locations confirmed on ≥ 2 additional consecutive tests. Risk factors for the development of VF defects were analyzed by COX proportional hazard models. After conversion into common logarithmic units, the rates of change of global VF indices were fitted with linear mixed models. RESULTS: FDT detected more eyes that developed VF defects than SAP using the less conservative criterion, and no significant difference was observed using the more conservative criterion. For those eyes detected by both SAP and FDT, FDT detected the development of VF defects either earlier than SAP or simultaneously in most cases. Baseline structural measurements were not significantly associated with an increased risk for the development of glaucomatous VF defects on either SAP or FDT. Older age was significantly associated with the development of VF defects on FDT but not on SAP. Both SAP and FDT detected a progressing worsening trend of pattern standard deviation over time with a similar rate of change between these test types. CONCLUSIONS: Matrix FDT would be useful to monitor the onset of VF defects in glaucoma suspects and may outperform SAP in the early stage of glaucomatous VF damage.Item Prediction accuracy of a novel dynamic structure-function model for glaucoma progression(Association for Research in Vision and Opthalmology, 2014-12) Hu, Rongrong; Marín-Franch, Iván; Racette, Lyne; Department of Ophthalmology, IU School of MedicinePURPOSE: To assess the prediction accuracy of a novel dynamic structure-function (DSF) model to monitor glaucoma progression. METHODS: Longitudinal data of paired rim area (RA) and mean sensitivity (MS) from 220 eyes with ocular hypertension or primary open-angle glaucoma enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. Rim area and MS were expressed as percent of mean normal based on an independent dataset of 91 healthy eyes. The DSF model uses centroids as estimates of the current state of the disease and velocity vectors as estimates of direction and rate of change over time. The first three visits were used to predict the fourth visit; the first four visits were used to predict the fifth visit, and so on up to the 11th visit. The prediction error (PE) was compared to that of ordinary least squares linear regression (OLSLR) using Wilcoxon signed-rank test. RESULTS: For predictions at visit 4 to visit 7, the average PE for the DSF model was significantly lower than OLSLR by 1.19% to 3.42% of mean normal. No significant difference was observed for the predictions at visit 8 to visit 11. The DSF model had lower PE than OLSLR for 70% of eyes in predicting visit 4 and approximately 60% in predicting visits 5, 6, and 7. CONCLUSIONS: The two models had similar prediction capabilities, and the DSF model performed better in shorter time series. The DSF model could be clinically useful when only limited follow-ups are available. (ClinicalTrials.gov numbers, NCT00221923, NCT00221897.).Item Prediction Accuracy of the Dynamic Structure-Function Model for Glaucoma Progression Using Contrast Sensitivity Perimetry and Confocal Scanning Laser Ophthalmoscopy(Wolters Kluwer, 2018-09) Ramezani, Koosha; Marín-Franch, Iván; Hu, Rongrong; Swanson, William H.; Racette, Lyne; Ophthalmology, School of MedicinePURPOSE: The purpose of this study was to determine whether combining a structural measure with contrast sensitivity perimetry (CSP), which has lower test-retest variability than static automated perimetry (SAP), reduces prediction error with 2 models of glaucoma progression. METHODS: In this retrospective analysis, eyes with 5 visits with rim area (RA), SAP, and CSP measures were selected from 2 datasets. Twenty-six eyes with open-angle glaucoma were included in the analyses. For CSP and SAP, mean sensitivity (MS) was obtained by converting the sensitivity values at each location from decibel (SAP) or log units (CSP) to linear units, and then averaging all values. MS and RA values were expressed as percent of mean normal based on independent normative data. Data from the first 3 and 4 visits were used to calculate errors in prediction for the fourth and fifth visits, respectively. Prediction errors were obtained for simple linear regression and the dynamic structure-function (DSF) model. RESULTS: With linear regression, the median prediction errors ranged from 6% to 17% when SAP MS and RA were used and from 9% to 17% when CSP MS and RA were used. With the DSF model, the median prediction errors ranged from 6% to 11% when SAP MS and RA were used and from 7% to 16% when CSP MS and RA were used. CONCLUSIONS: The DSF model had consistently lower prediction errors than simple linear regression. The lower test-retest variability of CSP in glaucomatous defects did not, however, result in lower prediction error.