- Browse by Author
Browsing by Author "Helmy, Ahdy"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Dynamic thermal/acoustic response for human bone materials at different energy levels: A diagnosis approach(Elsevier, 2016-10-31) Thella, Ashok Kumar; Rizkalla, James; Rathi, Neeraj; Kakani, Monika; Helmy, Ahdy; Salama, Paul; Rizkalla, Maher E.; Electrical and Computer Engineering, School of Engineering and TechnologyBackground The non-invasive diagnostic approaches have gained high attention in recent years, utilizing high technology sensor systems, including infrared, microwave devices, acoustic transducers, etc. The patient safety, high resolution images, and reliability are among the driving forces toward high technology approaches. The thermal and acoustic responses of the materials may reflect the important research parameters such as penetration depth, power consumption, and temperature change used for the practical models of the system. This paper emphasizes the approach for orthopedic application where the bone densities were considered in simulation to designate the type of human bones. Methods Thermal energy pulses were applied in order to study the penetration depth, the maximum temperature change; spatially and dynamically, and the acoustic pressure distribution over the bone thickness. The study was performed to optimize the amount of energy introduced into the materials that generate the temperature value for high resolution beyond the noise level. Results Three different energy pulses were used; 1 J, 3 J and 5 J. The thermal energy applied to the four bone materials, cancellous bone, cortical bone, red bone marrow, and yellow bone marrow were producing relative changes in temperature. The maximum change ranges from 0.5 K to 2 K for the applied pulses. The acoustic pressure also ranges from 210 to 220 dB among the various types of bones. Conclusion The results obtained from simulation suggest that a practical model utilizing infra-red scanning probe and piezoelectric devices may serve for the orthopedic diagnostic approach. The simulations for multiple layers such as skin interfaced with bone will be reserved for future considerations.Item Non-invasive photo acoustic approach for human bone diagnosis(Elsevier, 2016-08-03) Thella, Ashok Kumar; Rizkalla, James; Helmy, Ahdy; Suryadevara, Vinay Kumar; Salama, Paul; Rizkalla, Maher; Electrical and Computer Engineering, School of Engineering and TechnologyThe existing modalities of bone diagnosis including X-ray and ultrasound may cite drawback in some cases related to health issues and penetration depth, while the ultrasound modality may lack image quality. Photo acoustic approach however, provides light energy to the acoustic wave, enabling it to activate and respond according to the propagating media (which is type of bones in this case). At the same time, a differential temperature change may result in the bio heat response, resulting from the heat absorbed across the multiple materials under study. In this work, we have demonstrated the features of using photo acoustic modality in order to non-invasively diagnose the type of human bones based on their electrical, thermal, and acoustic properties that differentiate the output response of each type. COMSOL software was utilized to combine both acoustic equations and bio heat equations, in order to study both the thermal and acoustic responses through which the differential diagnosis can be obtained. In this study, we solved both the acoustic equation and bio heat equations for four types of bones, bone (cancellous), bone (cortical), bone marrow (red), and bone marrow (yellow). 1 MHz acoustic source frequency was chosen and 105 W/m2 power source was used in the simulation. The simulation tested the dynamic response of the wave over a distance of 5 cm from each side for the source. Near 2.4 cm was detected from simulation from each side of the source with a temperature change of within 0.5 K for various types of bones, citing a promising technique for a practical model to detect the type of bones via the differential temperature as well as the acoustic was response via the multiple materials associated with the human bones (skin and blood)., The simulation results suggest that the PA technique may be applied to non-invasive diagnosis for the different types of bones, including cancerous bones. A practical model for detecting both the temperature change via IR sensors, and acoustic wave signals may be detected via sensitive pressure transducer, which is reserved for future realization.