- Browse by Author
Browsing by Author "Gregor, Lennon"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Culture-Negative Neutrocytic Ascites in a Patient With Cardiac Ascites From End-Stage Heart Failure(Springer Nature, 2024-03-08) Ormachea, Kori X.; Gregor, Lennon; Quintero, Janina; George, Bistees; Singh, Sandeep; Medicine, School of MedicineThere are two significant groups of infection regarding ascitic fluid: spontaneous bacterial peritonitis (SBP) and culture-negative neutrocytic ascites (CNNA). SBP and CNNA typically occur in patients with cirrhosis. A 46-year-old male with end-stage biventricular heart failure presented with a heart failure exacerbation. He was treated with intravenous diuretics with the improvement of hypervolemia. He remained hospitalized to undergo an evaluation for tricuspid valve repair, but given the severity of his bi-ventricular heart failure, he underwent a heart transplant evaluation. As part of the work-up, he underwent an abdominal ultrasound that was significant for severe ascites but did not note an abnormal hepatic architecture suggestive of cirrhosis. A liver biopsy was then performed, which confirmed no evidence of cirrhosis. His hospitalization was complicated by refractory cardiac ascites, which required a bi-weekly paracentesis. The serum albumin-ascites gradient (SAAG) from his initial paracentesis was 1.4, indicating the etiology was from portal hypertension. The total protein was greater than 2.5 in multiple studies, so the etiology was less concerning for cirrhosis and secondary to his heart failure. About two weeks into his hospital course, he developed a leukocytosis but remained hemodynamically stable and asymptomatic from an infectious standpoint. Analysis of his ascitic fluid initially was negative for infection, but he later developed an elevated total neutrophil count on a subsequent ascitic fluid analysis study. The body fluid culture remained negative for bacterial growth. Hepatology was consulted, and he met the criteria for CNNA, so treatment with ceftriaxone was initiated. After initiating antibiotics, his leukocytosis and elevated ascitic fluid total neutrophil count resolved. Ascitic infections such as CNNA generally occur in patients with liver cirrhosis but may occur in patients without cirrhosis, as observed in our patient. This case highlights that patients with cardiac ascites can develop ascitic fluid infections that may have an impact on their mortality. The precipitating factor that enabled the patient to develop CNNA is unclear but may be related to the translocation of bacteria during his congestive heart failure exacerbation. Although uncommon in a patient with cardiac ascites, an early diagnosis of CNNA and the initiation of antibiotics can be important in preventing patient mortality.Item Pyloric Functional Lumen Imaging Probe Measurements Are Dependent on Balloon Position(The Korean Society of Neurogastroenterology and Motility, 2023) Yim, Brandon; Gregor, Lennon; Siwiec, Robert M.; Al-Haddad, Mohammad; Nowak, Thomas V.; Wo, John M.; Medicine, School of MedicineBackground/aims: The functional lumen imaging probe (FLIP) device has been used to assess pyloric dysfunction in patients with gastroparesis. We aim to investigate whether varying FLIP catheter positions affect pyloric FLIP measurements. Methods: Patients undergoing endoscopy for chronic unexplained nausea and vomiting (CUNV) or gastroparesis were prospectively enrolled. FLIP balloon was adjusted for 3 positions within the pylorus: (1) proximal position, 75% of FLIP balloon in the duodenum and 25% in the antrum; (2) middle position, 50% in the duodenum and 50% in the antrum; and (3) distal position, 25% in the duodenum and 75% in the antrum. Pylorus cross-sectional area (CSA), intra-bag pressure (P), and distensibility indices (DI) were measured for 30, 40, and 50-mL balloon volumes. Fluoroscopic images were obtained to confirm FLIP balloon geometry. Data was analyzed separately using FLIP Analytic and customized MATLAB software. Results: Twenty-two patients with CUNV (n = 4) and gastroparesis (n = 18) were enrolled. Pressures were significantly higher in the proximal position compared to the middle and distal positions. CSA measurements were significantly higher at the proximal and middle positions for 30-mL and 40-mL volume compared to the distal position values. DI values were significantly lower at the proximal positions for 40-mL and 50-mL distensions when compared to the middle and distal positions. Fluoroscopic images confirmed increased balloon bending when placed mostly in the duodenum. Conclusions: FLIP balloon position within the pylorus directly affects balloon geometry which significantly affects P, CSA, and DI measurements. Standardized pyloric FLIP protocols and balloon design adjustments are needed for the continued application of this technology to the pylorus.