- Browse by Author
Browsing by Author "Gates, Vanessa"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Direct comparison and reproducibility of two segmentation methods for multicompartment dosimetry: round robin study on radioembolization treatment planning in hepatocellular carcinoma(Springer, 2023) Lam, Marnix; Garin, Etienne; Palard‑Novello, Xavier; Mahvash, Armeen; Kappadath, Cheenu; Haste, Paul; Tann, Mark; Herrmann, Ken; Barbato, Francesco; Geller, Brian; Schaefer, Niklaus; Denys, Alban; Dreher, Matthew; Fowers, Kirk D.; Gates, Vanessa; Salem, Riad; Radiology and Imaging Sciences, School of MedicinePurpose: Investigate reproducibility of two segmentation methods for multicompartment dosimetry, including normal tissue absorbed dose (NTAD) and tumour absorbed dose (TAD), in hepatocellular carcinoma patients treated with yttrium-90 (90Y) glass microspheres. Methods: TARGET was a retrospective investigation in 209 patients with < 10 tumours per lobe and at least one tumour ≥ 3 cm ± portal vein thrombosis. Dosimetry was compared using two distinct segmentation methods: anatomic (CT/MRI-based) and count threshold-based on pre-procedural 99mTc-MAA SPECT. In a round robin substudy in 20 patients with ≤ 5 unilobar tumours, the inter-observer reproducibility of eight reviewers was evaluated by computing reproducibility coefficient (RDC) of volume and absorbed dose for whole liver, whole liver normal tissue, perfused normal tissue, perfused liver, total perfused tumour, and target lesion. Intra-observer reproducibility was based on second assessments in 10 patients ≥ 2 weeks later. Results: 99mTc-MAA segmentation calculated higher absorbed doses compared to anatomic segmentation (n = 209), 43.9% higher for TAD (95% limits of agreement [LoA]: - 49.0%, 306.2%) and 21.3% for NTAD (95% LoA: - 67.6%, 354.0%). For the round robin substudy (n = 20), inter-observer reproducibility was better for anatomic (RDC range: 1.17 to 3.53) than 99mTc-MAA SPECT segmentation (1.29 to 7.00) and similar between anatomic imaging modalities (CT: 1.09 to 3.56; MRI: 1.24 to 3.50). Inter-observer reproducibility was better for larger volumes. Perfused normal tissue volume RDC was 1.95 by anatomic and 3.19 by 99mTc-MAA SPECT, with corresponding absorbed dose RDC 1.46 and 1.75. Total perfused tumour volume RDC was higher, 2.92 for anatomic and 7.0 by 99mTc-MAA SPECT with corresponding absorbed dose RDC of 1.84 and 2.78. Intra-observer variability was lower for perfused NTAD (range: 14.3 to 19.7 Gy) than total perfused TAD (range: 42.8 to 121.4 Gy). Conclusion: Anatomic segmentation-based dosimetry, versus 99mTc-MAA segmentation, results in lower absorbed doses with superior reproducibility. Higher volume compartments, such as normal tissue versus tumour, exhibit improved reproducibility.Item Utility of pre-procedural [99mTc]TcMAA SPECT/CT Multicompartment Dosimetry for Treatment Planning of 90Y Glass microspheres in patients with Hepatocellular Carcinoma: comparison of anatomic versus [99mTc]TcMAA-based Segmentation(Springer, 2025) Lam, Marnix; Garin, Etienne; Haste, Paul; Denys, Alban; Geller, Brian; Kappadath, S. Cheenu; Turkmen, Cuneyt; Sze, Daniel Y.; Alsuhaibani, Hamad Saleh; Herrmann, Ken; Maccauro, Marco; Cantasdemir, Murat; Dreher, Matthew; Fowers, Kirk D.; Gates, Vanessa; Salem, Riad; Radiology and Imaging Sciences, School of MedicinePurpose: Pre-treatment [99mTc]TcMAA-based radioembolization treatment planning using multicompartment dosimetry involves the definition of the tumor and normal tissue compartments and calculation of the prescribed absorbed doses. The aim was to compare the real-world utility of anatomic and [99mTc]TcMAA-based segmentation of tumor and normal tissue compartments. Materials and methods: Included patients had HCC treated by glass [90Y]yttrium microspheres, ≥ 1 tumor, ≥ 3 cm diameter and [99mTc]TcMAA SPECT/CT imaging before treatment. Segmentation was performed retrospectively using dedicated dosimetry software: (1) anatomic (diagnostic CT/MRI-based), and (2) [99mTc]TcMAA threshold-based (i.e., using an activity-isocontour threshold). CT/MRI was co-registered with [99mTc]TcMAA SPECT/CT. Logistic regression and Cox regression, respectively, were used to evaluate relationships between total perfused tumor absorbed dose (TAD) and objective response rate (ORR) and overall survival (OS). In a subset-analysis pre- and post-treatment dosimetry were compared using Bland-Altman analysis and Pearson's correlation coefficient. Results: A total of 209 patients were enrolled. Total perfused tumor and normal tissue volumes were larger when using anatomic versus [99mTc]TcMAA threshold segmentation, resulting in lower absorbed doses. mRECIST ORR was higher with increasing total perfused TAD (odds ratio per 100 Gy TAD increase was 1.22 (95% CI: 1.01-1.49; p = 0.044) for anatomic and 1.19 (95% CI: 1.04-1.37; p = 0.012) for [99mTc]TcMAA threshold segmentation. Higher total perfused TAD was associated with improved OS (hazard ratio per 100 Gy TAD increase was 0.826 (95% CI: 0.714-0.954; p = 0.009) and 0.847 (95% CI: 0.765-0.936; p = 0.001) for anatomic and [99mTc]TcMAA threshold segmentation, respectively). For pre- vs. post-treatment dosimetry comparison, the average bias for total perfused TAD was + 11.5 Gy (95% limits of agreement: -227.0 to 250.0) with a strong positive correlation (Pearson's correlation coefficient = 0.80). Conclusion: Real-world data support [99mTc]TcMAA imaging to estimate absorbed doses prior to treatment of HCC with glass [90Y]yttrium microspheres. Both anatomic and [99mTc]TcMAA threshold methods were suitable for treatment planning.