ScholarWorksIndianapolis
  • Communities & Collections
  • Browse ScholarWorks
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Ethier, C. Ross"

Now showing 1 - 4 of 4
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Characterization, Enrichment, and Computational Modeling of Cross-Linked Actin Networks in Transformed Trabecular Meshwork Cells
    (Association for Research in Vision and Ophthalmology, 2025) Li, Haiyan; Harvey, Devon H.; Dai, Jiannong; Swingle, Steven P.; Compton, Anthony M.; Sugali, Chenna Kesavulu; Dhamodaran, Kamesh; Yao, Jing; Lin, Tsai-Yu; Sulchek, Todd; Kim, Taeyoon; Ethier, C. Ross; Mao, Weiming; Ophthalmology, School of Medicine
    Purpose: Cross-linked actin networks (CLANs) are prevalent in the glaucomatous trabecular meshwork (TM). We previously developed the GTM3L cell line, which spontaneously forms fluorescently labeled CLANs, by transducing GTM3, a transformed glaucomatous TM cell line, with a lentivirus expressing the LifeAct-GFP fusion protein. Here, we determined if LifeAct-GFP viral copy numbers are associated with CLANs, developed approaches to increase CLAN incidence, and computationally studied the biomechanical properties of CLAN-containing GTM3L cells. Methods: GTM3L cells were fluorescently sorted for viral copy number analysis to determine whether increased CLAN incidence was associated with copy number. CLAN incidence was increased by combining (1) differential adhesion sorting, (2) cell deswelling, and (3) cell stiffness selection. GTM3L cells were cultured on glass or soft hydrogels for stiffness measurement by atomic force microscopy. Computational models studied the biomechanical properties of CLANs. Results: GTM3L cells had one LifeAct-GFP viral copy/cell on average, and viral copy number or LifeAct-GFP expression level did not associate with CLAN incidence rate. However, CLAN rate was increased from -0.28% to -50% by combining the three enrichment methods noted above. Further, GTM3L cells formed more CLANs on a stiff versus a soft substrate. Computational modeling predicted that CLANs contribute to higher cell stiffness, including increased resistance of the nucleus to tensile stress when CLANs are physically linked to the nucleus. Conclusions: It is possible to greatly enhance CLAN incidence in GTM3L cells. CLANs are mechanosensitive structures that affect cell biomechanical properties. Further research is needed to determine the biomechanics, mechanobiology, and etiology of CLANs in the TM.
  • Loading...
    Thumbnail Image
    Item
    Consensus Recommendation for Mouse Models of Ocular Hypertension to Study Aqueous Humor Outflow and Its Mechanisms
    (Association for Research in Vision and Ophthalmology, 2022) McDowell, Colleen M.; Kizhatil, Krishnakumar; Elliott, Michael H.; Overby, Darryl R.; van Batenburg-Sherwood, Joseph; Millar, J. Cameron; Kuehn, Markus H.; Zode, Gulab; Acott, Ted S.; Anderson, Michael G.; Bhattacharya, Sanjoy K.; Bertrand, Jacques A.; Borras, Terete; Bovenkamp, Diane E.; Cheng, Lin; Danias, John; De Ieso, Michael Lucio; Du, Yiqin; Faralli, Jennifer A.; Fuchshofer, Rudolf; Ganapathy, Preethi S.; Gong, Haiyan; Herberg, Samuel; Hernandez, Humberto; Humphries, Peter; John, Simon W.M.; Kaufman, Paul L.; Keller, Kate E.; Kelley, Mary J.; Kelly, Ruth A.; Krizaj, David; Kumar, Ajay; Leonard, Brian C.; Lieberman, Raquel L.; Liton, Paloma; Liu, Yutao; Liu, Katy C.; Lopez, Navita N.; Mao, Weiming; Mavlyutov, Timur; McDonnell, Fiona; McLellan, Gillian J.; Mzyk, Philip; Nartey, Andrews; Pasquale, Louis R.; Patel, Gaurang C.; Pattabiraman, Padmanabhan P.; Peters, Donna M.; Raghunathan, Vijaykrishna; Rao, Ponugoti Vasantha; Rayana, Naga; Raychaudhuri, Urmimala; Reina-Torres, Ester; Ren, Ruiyi; Rhee, Douglas; Chowdhury, Uttio Roy; Samples, John R.; Samples, E. Griffen; Sharif, Najam; Schuman, Joel S.; Sheffield, Val C.; Stevenson, Cooper H.; Soundararajan, Avinash; Subramanian, Preeti; Sugali, Chenna Kesavulu; Sun, Yang; Toris, Carol B.; Torrejon, Karen Y.; Vahabikashi, Amir; Vranka, Janice A.; Wang, Ting; Willoughby, Colin E.; Xin, Chen; Yun, Hongmin; Zhang, Hao F.; Fautsch, Michael P.; Tamm, Ernst R.; Clark, Abbot F.; Ethier, C. Ross; Stamer, W. Daniel; Ophthalmology, School of Medicine
    Due to their similarities in anatomy, physiology, and pharmacology to humans, mice are a valuable model system to study the generation and mechanisms modulating conventional outflow resistance and thus intraocular pressure. In addition, mouse models are critical for understanding the complex nature of conventional outflow homeostasis and dysfunction that results in ocular hypertension. In this review, we describe a set of minimum acceptable standards for developing, characterizing, and utilizing mouse models of open-angle ocular hypertension. We expect that this set of standard practices will increase scientific rigor when using mouse models and will better enable researchers to replicate and build upon previous findings.
  • Loading...
    Thumbnail Image
    Item
    Consensus Recommendation for Mouse Models of Ocular Hypertension to Study Aqueous Humor Outflow and Its Mechanisms
    (ARVO, 2022-02) McDowell, Colleen M.; Kizhatil, Krishnakumar; Elliott, Michael H.; Overby, Darryl R.; Van Batenburg-Sherwood, Joseph; Millar, J. Cameron; Kuehn, Markus H.; Zode, Gulab; Acott, Ted S.; Anderson, Michael G.; Bhattacharya, Sanjoy K.; Bertrand, Jacques A.; Borras, Terete; Bovenkamp, Diane E.; Cheng, Lin; Danias, John; De Ieso, Michael Lucio; Du, Yiqin; Faralli, Jennifer A.; Fuchshofer, Rudolf; Ganapathy, Preethi S.; Gong, Haiyan; Herberg, Samuel; Hernandez, Humberto; Humphries, Peter; John, Simon W. M.; Kaufman, Paul L.; Keller, Kate E.; Kelley, Mary J.; Kelly, Ruth A.; Krizaj, David; Kumar, Ajay; Leonard, Brian C.; Lieberman, Raquel L.; Liton, Paloma; Liu, Yutao; Liu, Katy C.; Lopez, Navita N.; Mao, Weiming; Mavlyutov, Timur; McDonnell, Fiona; McLellan, Gillian J.; Mzyk, Philip; Nartey, Andrews; Pasquale, Louis R.; Patel, Gaurang C.; Pattabiraman, Padmanabhan P.; Peters, Donna M.; Raghunathan, Vijaykrishna; Rao, Ponugoti Vasantha; Rayana, Naga; Raychaudhuri, Urmimala; Reina-Torres, Ester; Ren, Ruiyi; Rhee, Douglas; Chowdhury, Uttio Roy; Samples, John R.; Samples, E. Griffen; Sharif, Najam; Schuman, Joel S.; Sheffield, Val C.; Stevenson, Cooper H.; Soundararajan, Avinash; Subramanian, Preeti; Sugali, Chenna Kesavulu; Sun, Yang; Toris, Carol B.; Torrejon, Karen Y.; Vahabikashi, Amir; Vranka, Janice A.; Wang, Ting; Willoughby, Colin E.; Xin, Chen; Yun, Hongmin; Zhang, Hao F.; Fautsch, Michael P.; Tamm, Ernst R.; Clark, Abbot F.; Ethier, C. Ross; Stamer, W. Daniel; Ophthalmology, School of Medicine
    Due to their similarities in anatomy, physiology, and pharmacology to humans, mice are a valuable model system to study the generation and mechanisms modulating conventional outflow resistance and thus intraocular pressure. In addition, mouse models are critical for understanding the complex nature of conventional outflow homeostasis and dysfunction that results in ocular hypertension. In this review, we describe a set of minimum acceptable standards for developing, characterizing, and utilizing mouse models of open-angle ocular hypertension. We expect that this set of standard practices will increase scientific rigor when using mouse models and will better enable researchers to replicate and build upon previous findings.
  • Loading...
    Thumbnail Image
    Item
    Consensus Recommendations for Studies of Outflow Facility and Intraocular Pressure Regulation Using Ex Vivo Perfusion Approaches
    (Association for Research in Vision and Ophthalmology, 2024) Acott, Ted S.; Fautsch, Michael P.; Mao, Weiming; Ethier, C. Ross; Huang, Alex S.; Kelley, Mary J.; Aga, Mini; Bhattacharya, Sanjoy K.; Borras, Terete; Bovenkamp, Diane; Chowdhury, Uttio Roy; Clark, Abbot F.; Dibas, Mohammed I.; Du, Yiqin; Elliott, Michael H.; Faralli, Jennifer A.; Gong, Haiyan; Herberg, Samuel; Johnstone, Murray A.; Kaufman, Paul L.; Keller, Kate E.; Kelly, Ruth A.; Krizaj, David; Kuehn, Markus H.; Li, Hoi Lam; Lieberman, Raquel; Lin, Shan C.; Liu, Yutao; McDonnell, Fiona S.; McDowell, Colleen M.; McLellan, Gillian J.; Mzyk, Philip; Nair, Kayarat Saidas; Overby, Darryl R.; Peters, Donna M.; Raghunathan, VijayKrishna; Rao, Ponugoti Vasantha; Roddy, Gavin W.; Sharif, Najam A.; Shim, Myoung Sup; Sun, Yang; Thomson, Benjamin R.; Toris, Carol B.; Willoughby, Colin E.; Zhang, Hao F.; Freddo, Thomas F.; Fuchshofer, Rudolf; Hill, Kamisha R.; Karimi, Alireza; Kizhatil, Krishnakumar; Kopcyznski, Casey C.; Liton, Paloma; Patel, Gaurang; Peng, Michael; Pattabiraman, Padmanabhan P.; Prasanna, Ganesh; Reina-Torres, Ester; Samples, E. Griffen; Samples, John R.; Steel, Cynthia L.; Strohmaier, Clemens A.; Subramanian, Preeti; Sugali, Chenna Kesavulu; van Batenburg-Sherwood, Joseph; Wong, Cydney; Youngblood, Hannah; Zode, Gulab S.; White, Elizabeth; Stamer, W. Daniel; Ophthalmology, School of Medicine
    Intraocular pressure (IOP) elevation is the primary risk factor and currently the main treatable factor for progression of glaucomatous optic neuropathy. In addition to direct clinical and living animal in vivo studies, ex vivo perfusion of anterior segments and whole eyes is a key technique for studying conventional outflow function as it is responsible for IOP regulation. We present well-tested experimental details, protocols, considerations, advantages, and limitations of several ex vivo model systems for studying IOP regulation. These include: (1) perfused whole globes, (2) stationary anterior segment organ culture, (3) perfused human anterior segment organ culture, (4) perfused animal anterior segment organ culture, (5) perfused human corneal rims, and (6) perfused human anterior segment wedges. These methods, with due consideration paid to their strengths and limitations, comprise a set of very strong tools for extending our understanding of IOP regulation.
About IU Indianapolis ScholarWorks
  • Accessibility
  • Privacy Notice
  • Copyright © 2025 The Trustees of Indiana University