- Browse by Author
Browsing by Author "Dolejs, Scott"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Pancreatic cyst fluid glucose: rapid, inexpensive, and accurate diagnosis of mucinous pancreatic cysts(Elsevier, 2018-03) Carr, Rosalie A.; Yip-Schneider, Michele T.; Simpson, Rachel E.; Dolejs, Scott; Schneider, Justine G.; Huangbing, Wu; Ceppa, Eugene P.; Park, Walter; Schmidt, C. Max; Surgery, School of MedicineBackground The most widely accepted biochemical test for preoperative differentiation of mucinous from benign, nonmucinous pancreatic cysts is cyst fluid carcinoembryonic antigen. However, the diagnostic accuracy of carcinoembryonic antigen ranges from 70% to 86%. Based on previous work, we hypothesize that pancreatic cyst fluid glucose may be an attractive alternative to carcinoembryonic antigen. Methods Pancreatic cyst fluid was collected during endoscopic or operative intervention. Diagnoses were pathologically confirmed. Glucose and carcinoembryonic antigen were measured using a patient glucometer and automated analyzer/enzyme-linked immunosorbent assay. Sensitivity, specificity, accuracy, and receiver operator characteristic analyses were performed. Results Cyst fluid samples from 153 patients were evaluated (mucinous: 25 mucinous cystic neoplasms, 77 intraductal papillary mucinous neoplasms, 4 ductal adenocarcinomas; nonmucinous: 21 serous cystic neoplasms, 9 cystic neuroendocrine tumors, 14 pseudocysts, 3 solid pseudopapillary neoplasms). Median cyst fluid glucose was lower in mucinous versus nonmucinous cysts (19 vs 96 mg/dL; P < .0001). With a threshold of ≤ 50 mg/dL, cyst fluid glucose was 92% sensitive, 87% specific, and 90% accurate in diagnosing mucinous pancreatic cysts. In comparison, cyst fluid carcinoembryonic antigen with a threshold of >192 ng/mL was 58% sensitive, 96% specific, and 69% accurate. Area under the curve for glucose and CEA were similar at 0.91 and 0.92. Conclusion Cyst fluid glucose has significant advantages over carcinoembryonic antigen and should be considered for use as a routine diagnostic test for pancreatic mucinous cysts.Item Pancreatic Cyst Fluid Vascular Endothelial Growth Factor A and Carcinoembryonic Antigen: A Highly Accurate Test for the Diagnosis of Serous Cystic Neoplasm(Elsevier, 2017-07) Carr, Rosalie A.; Yip-Schneider, Michele T.; Dolejs, Scott; Hancock, Bradley A.; Wu, Huangbing; Radovich, Milan; Schmidt, C. Max; Surgery, School of MedicineBackground Accurate differentiation of pancreatic cystic lesions is important for early detection and prevention of pancreatic cancer, as well as avoidance of unnecessary surgical intervention. Serous cystic neoplasms (SCNs) have no malignant potential, but can mimic the following premalignant mucinous cystic lesions: mucinous cystic neoplasm and intraductal papillary mucinous neoplasm (IPMN). We recently identified vascular endothelial growth factor (VEGF)-A as a novel pancreatic fluid biomarker for SCN. We hypothesize that combining cyst fluid CEA with VEGF-A will improve the diagnostic accuracy of VEGF-A. Methods Pancreatic cyst/duct fluid was collected from consenting patients undergoing surgical cyst resection with corresponding pathologic diagnoses. Pancreatic fluid VEGF-A and CEA levels were detected by ELISA. Results One hundred and forty-nine patients with pancreatic cystic lesions met inclusion criteria. Pathologic diagnoses included pseudocyst (n = 14), SCN (n = 26), mucinous cystic neoplasm (n = 40), low-/moderate-grade IPMN (n = 34), high-grade IPMN (n = 20), invasive IPMN (n = 10), and solid pseudopapillary neoplasm (n = 5). Vascular endothelial growth factor A was significantly elevated in SCN cyst fluid compared with all other diagnoses (p < 0.001). With a threshold of >5,000 pg/mL, VEGF-A alone has 100% sensitivity and 83.7% specificity to distinguish SCNs from other cystic lesions. With a threshold of ≤10 ng/mL, CEA alone identifies SCN with 95.5% sensitivity and 81.5% specificity. Sensitivity and specificity of the VEGF-A/CEA combination are 95.5% and 100%, respectively. The c-statistic increased from 0.98 to 0.99 in the receiver operating characteristic analysis when CEA was added to VEGF-A alone. Conclusions Although VEGF-A alone is a highly accurate test for SCN, the combination of VEGF-A with CEA approaches the gold standard for pathologic diagnosis, importantly avoiding false positives. Patients with a positive test indicating benign SCN can be spared a high-risk surgical pancreatic resection.