- Browse by Author
Browsing by Author "Cho, Chang-Min"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study(Thieme Publishing Group, 2015-10) DeWitt, John; Cho, Chang-Min; Lin, Jingmei; Al-Haddad, Mohammad; Canto, Marcia Irene; Salamone, Ashley; Hruban, Ralph H.; Messallam, Ahmed A.; Khashab, Mouen A.; Department of Medicine, IU School of MedicineBACKGROUND AND STUDY AIMS: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United States) to a conventional 19-gauge Tru-Cut biopsy (EUS-TCB) needle (19G, Quick-Core, Cook Medical Inc.). PATIENTS AND METHODS: Patients referred for EUS who require possible histologic biopsy were prospectively randomized to EUS-FNB or EUS-TCB. With the initial needle, ≤ 3 biopsies were obtained until either technical failure or an adequate core was obtained. Patients with suspected inadequate biopsies were crossed over to the other needle and similarly ≤ 3 passes were obtained until adequate cores or technical failure occurred. Technical success, diagnostic histology, accuracy and complication rates were evaluated. RESULTS: Eighty-five patients (mean 58 years; 43 male) were randomized to FNB (n = 44) and TCB (n = 41) with seven patients excluded. Procedure indication, biopsy site, mass size, number of passes, puncture site, overall technical success and adverse events were similar between the two groups. FNB specimens had a higher prevalence of diagnostic histology (85 % vs. 57 %; P = 0.006), accuracy (88 % vs. 62 %; P = 0.02), mean total length (19.4 vs. 4.3 mm; P = 0.001), mean complete portal triads from liver biopsies (10.4 vs. 1.3; P = 0.0004) and required fewer crossover biopsies compared to those of TCB (2 % vs. 65 %; P = 0.0001). Overall technical success and complication rates were comparable. CONCLUSION: EUS-FNB using a 19-gauge FNB needle is superior to 19-gauge EUS-TCB needle.Item Rescue Endoscopic Ultrasound (EUS)-Guided Trucut Biopsy Following Suboptimal EUS-Guided Fine Needle Aspiration for Mediastinal Lesions(Editorial Office of Gut and Liver, 2013-03) Cho, Chang-Min; Al-Haddad, Mohammad; LeBlanc, Julia K.; Sherman, Stuart; McHenry, Lee; DeWitt, JohnBackground/Aims Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) and Trucut biopsy (TCB) are sensitive techniques for diagnosing mediastinal lesions, but it is unclear how either one or both should be used to obtain a pathologic diagnosis. The objective of our study was to evaluate whether EUS-TCB impacts the diagnosis of mediastinal lesions after the initial on-site review of EUS-FNA specimen suggests a suboptimal result. Methods We enrolled consecutive patients with mediastinal lesions who underwent EUS-TCB during the same procedure if the initial EUS-FNA demonstrated an inadequate FNA sample or suggested that histopathology was required for diagnosis. Diagnostic accuracies between procedures were compared as the main outcome. Results Twenty-seven patients (14 men; median age, 56 years; range, 19 to 82 years) underwent EUS-FNA and EUS-TCB to evaluate a mediastinal lymphadenopathy or mass (n=17), to determine the cancer stage (n=3) or to exclude tumor recurrence or metastasis (n=7). The overall diagnostic accuracies of EUS-FNA and EUS-TCB were 78% and 67%, respectively (p=0.375). The combined diagnostic accuracy of EUS-FNA plus EUS-TCB was 82%. In six patients with nondiagnostic EUS-FNA, EUS-TCB provided a final diagnosis in one patient (17%). Conclusions In the current series of patients with mediastinal masses or adenopathy, the administration of EUS-TCB following suboptimal results for the on-site cytology review did not increase the diagnostic yield.