- Browse by Author
Browsing by Author "Bohnstedt, Bradley"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Intracranial Vasospasm After Evacuation of Acute Spontaneous Subdural Hematoma(Cureus, 2021-05-27) Witten, Andrew J.; Ordaz, Josue D.; Alentado, Vincent J.; Bohnstedt, Bradley; Neurological Surgery, School of MedicineCerebral vasospasm is a well-known entity following aneurysmal subarachnoid hemorrhage. While it has been described in trauma, it has been much less studied. There have been no previous reports of cerebral vasospasm following spontaneous subdural hematoma or after subdural hematoma evacuation. In this case report, we present a 38-year-old otherwise healthy female who suffered an acute spontaneous subdural hematoma. After surgical evacuation of her hematoma, she developed neurologic decline. Computer tomography angiography demonstrated intracranial vasospasm. She was treated with blood pressure augmentation and nimodipine. She went on to make a full neurologic recovery.To our knowledge, this is the first reported case of cerebral vasospasm after acute spontaneous subdural hematoma or after subdural hematoma evacuation, and the patient recovered without sequelae. The promising outcome of this case may provide a framework for future similar cases. Neurosurgeons and intensivists should keep cerebral vasospasm in their differentials for patients who have neurologic decline after craniotomy for acute subdural hematoma and have an otherwise negative scan for new acute abnormality.Item Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis(BMJ, 2021-02) Starke, Robert M.; Park, Min S.; Bellon, Richard; Bohnstedt, Bradley; Schirmer, Clemens M.; Leacy, Reade De; Fiorella, David; Yoo, Albert J.; Spiotta, Alejandro M.; Neurological Surgery, School of MedicineBackground Using data from the SMART registry, we report on periprocedural safety of the Penumbra SMART Coil System for endovascular coil embolization of saccular intracranial aneurysms. Methods The SMART registry was a prospective, multi-center registry of site standard of care endovascular coiling procedures performed using at least 75% Penumbra SMART Coil, PC400, and/or POD coils. This subset analysis reports on the periprocedural safety outcomes of the saccular intracranial aneurysm cohort. Predictors of rupture/re-rupture or perforation (RRP), thromboembolic complications, and device- or procedure-related adverse events (AEs) were determined in univariate and multivariate analysis. Results Between June 2016 and August 2018, 851 saccular aneurysm patients (31.0%, 264/851 ruptured) were enrolled across 66 North American centers. Clinically significant (ie, a serious adverse event) RRP occurred in 2.0% (17/851) of cases – 1.9% (5/264) for the ruptured cohort and 2.0% (12/587) for the un-ruptured cohort. Clinically significant thromboembolic events occurred in 3.1% (26/851) of cases – 5.3% (14/264) for the ruptured cohort and 2.0% (12/587) for the un-ruptured cohort. Multivariate predictors of periprocedural RRP were increased packing density and adjunctive treatment with a balloon. For periprocedural thromboembolic events, multivariate predictors were bifurcation location and ruptured status. For device- or procedure-related AEs, multivariate predictors were bifurcation location and adjunctive treatment with stent or balloon. Conclusion The low rates of thromboembolic complications and RRP events demonstrate the adequate safety profile of the SMART Coil System to treat cerebral aneurysms in routine clinical practice.