Item A comparison of 2 distal attachment mucosal exposure devices: a noninferiority randomized controlled trial(Elsevier, 2019) Rex, Douglas K.; Sagi, Sashidhar V.; Kessler, William R.; Rogers, Nicholas A.; Fischer, Monika; Bohm, Matthew E.; Dewitt, John M.; Lahr, Rachel E.; Searight, Meghan P.; Sullivan, Andrew W.; McWhinney, Connor D.; Garcia, Jonathan R.; Broadley, Heather M.; Vemulapalli, Krishna C.; Medicine, School of MedicineBackground and Aims Endocuff and Endocuff Vision are effective mucosal exposure devices for improving polyp detection during colonoscopy. AmplifEYE is a knock-off device that appears similar to the Endocuff devices but has received minimal clinical testing. Methods We performed a randomized controlled clinical trial using a noninferiority design to compare Endocuff Vision with AmplifEYE. Results The primary endpoint of adenomas per colonoscopy was similar in AmplifEYE at 1.63 (2.83) versus 1.51 (2.29) with Endocuff Vision; p=0.535. The 95% lower confidence limit was 0.88 for ratio of means, establishing noninferiority of AmplifEYE (p=0.008). There was no difference between the arms in mean insertion time, and mean inspection time (withdrawal time minus polypectomy time and time for washing and suctioning) was shorter with AmplifEYE (6.8 minutes vs 6.9 minutes, p=0.042). Conclusions AmplifEYE is noninferior to Endocuff Vision for adenoma detection. The decision of which device to use can be based on cost. Additional comparisons of AmplifEYE to Endocuff by other investigators are warranted.Item Delayed Gastric Emptying Is Not Associated with a Microbiological Diagnosis of Small Intestinal Bacterial Overgrowth(Springer, 2021) Calderon, Gerardo; Siwiec, Robert M.; Bohm, Matthew E.; Nowak, Thomas V.; Wo, John M.; Gupta, Anita; Xu, Huiping; Shin, Andrea; Medicine, School of MedicineBackground: Clinical symptoms of patients with small intestinal bacterial overgrowth (SIBO) may overlap with symptoms of gastroparesis. Prior studies suggest delayed small intestinal transit is associated with SIBO, but have not shown an association between delayed gastric emptying and SIBO. However, these studies have generally relied on the indirect method of breath testing to diagnose SIBO. Aims: The aim of this study was to examine the association between a microbiological diagnosis of SIBO and delayed gastric emptying by scintigraphy. Methods: In a single-center retrospective study of previous research participants who presented for small bowel enteroscopy for diagnostic evaluation of SIBO, we identified 73 participants who underwent gastric emptying study by scintigraphy. A microbiological diagnosis of SIBO was made in patients based on culture results of jejunal aspirates. Clinical symptoms were assessed using the total gastroparesis cardinal symptom index (GCSI) score. We compared delayed gastric emptying, 2- and 4-h gastric retention, and gastroparesis symptoms between patients with and without a microbiological diagnosis of SIBO. Key results: Among 29 participants with SIBO and 44 without SIBO, 33 (45%) had evidence of delayed gastric emptying. There was no significant association between a microbiological diagnosis of SIBO and delayed gastric emptying by scintigraphy. Percent retained at 2 and 4 h, and total GCSI scores did not differ significantly between those with and without SIBO. Conclusions: Although delayed gastric emptying is common in patients with suspected SIBO, gastric emptying is not associated with a microbiological diagnosis of SIBO.Item Impact of a ring fitted cap on insertion time and adenoma detection: a randomized controlled trial(Elsevier, 2019) Rex, Douglas K.; Kessler, William R.; Sagi, Sashidhar V.; Rogers, Nicholas A.; Fischer, Monika; Bohm, Matthew E.; Wo, John M.; Dewitt, John M.; McHenry, Lee; Lahr, Rachel E.; Searight, Meghan P.; MacPhail, Margaret; Sullivan, Andrew W.; McWhinney, Connor D.; Vemulapalli, Krishna C.; Medicine, School of MedicineBackground and Aims: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring fitted cap (EndoRings, EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy. Methods: A single-center randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate (SSPDR), insertion times, withdrawal times, and ease of passage through the sigmoid colon. Results: EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, p=0.025) but there were no statistically significant differences in ADR or SSPDR. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with EndoRings and contributed substantially to the overall results. Conclusions: EndoRings can increase adenoma detection without significant increase in procedure time, but the effect varies between operators. EndoRings slows colonoscope insertion.