Reliability and validity of MRI-based automated volumetry software relative to auto-assisted manual measurement of subcortical structures in HIV-infected patients from a multisite study

Date
2010
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

The automated volumetric output of FreeSurfer and Individual Brain Atlases using Statistical Parametric Mapping (IBASPM), two widely used and well published software packages, was examined for accuracy and consistency relative to auto-assisted manual (AAM) tracings (i.e., manual correction of automated output) when measuring the caudate, putamen, amygdala, and hippocampus in the baseline scans of 120 HIV-infected patients (86.7% male, 47.3+/-6.3y.o., mean HIV duration 12.0+/-6.3years) from the NIH-funded HIV Neuroimaging Consortium (HIVNC) cohort. The data was examined for accuracy and consistency relative to auto-assisted manual tracing, and construct validity was assessed by correlating automated and AAM volumetric measures with relevant clinical measures of HIV progression. When results were averaged across all patients in the eight structures examined, FreeSurfer achieved lower absolute volume difference in five, higher sensitivity in seven, and higher spatial overlap in all eight structures. Additionally, FreeSurfer results exhibited less variability in all measures. Output from both methods identified discrepant correlations with clinical measures of HIV progression relative to AAM segmented data. Overall, FreeSurfer proved more effective in the context of subcortical volumetry in HIV-patients, particularly in a multisite cohort study such as this. These findings emphasize that regardless of the automated method used, visual inspection of segmentation output, along with manual correction if necessary, remains critical to ensuring the validity of reported results.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Dewey J, Hana G, Russell T, et al. Reliability and validity of MRI-based automated volumetry software relative to auto-assisted manual measurement of subcortical structures in HIV-infected patients from a multisite study. Neuroimage. 2010;51(4):1334-1344. doi:10.1016/j.neuroimage.2010.03.033
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
NeuroImage
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}