Abstract

Purpose: To investigate whether implantation of a glaucoma shunt device leads to inappropriate accumulation of plasma derived proteins in the aqueous humor.

Methods: Aqueous humor samples were collected from 11 patients (study group) with a glaucoma shunt device undergoing either cataract surgery or a corneal transplant and 11 patients (control) with senile cataract undergoing routine cataract extraction. Of the study group, 9 had an Ahmed valve implant and 2 eyes had a Baerveldt implant. Tryptic digests of the mixture of proteins in aqueous humor (AH) were analyzed using Liquid Chromatography/Mass Spectrometry (LC-MS/MS). Proteins were identified with high confidence using stringent criteria and compared quantitatively using a label-free platform (IdentiQuantXL™).

Results: We identified 135 proteins in the albumin-depleted fraction in both the study and control group AH. Using stringent criteria, 13 proteins were detected at a significantly higher level compared to controls. These proteins are known to play a role in oxidative stress, apoptosis, inflammation and/or immunity and include gelsolin (p=0.00005), plasminogen (p=0.00009), angiotensinogen (p=0.0001), apolipoprotein A-II (p=0.0002), beta-2-microglobulin (p=0.0002), dickkopf-3 (DKK-3; p=0.0002), pigment epithelium-derived factor (p=0.0002), RIG-like 7-1 (p=0.0002), afamin (p=0.0003), fibronectin 1 (FN1; p=0.0003), apolipoprotein A-I (p=0.0004), activated complement C4 protein (C4a; p=0.0004) and prothrombin (p=0.0004). Many of the identified proteins were novel proteins that have not been associated with glaucoma in prior studies. All but C4a (complement C4 is a plasma protein but not in an activated form) are known plasma proteins and the elevated levels of these proteins in the aqueous humor suggests a breach in the blood-aqueous barrier with passive influx into the anterior chamber of the eye.

Conclusions: The presence of these proteins in the aqueous humor suggests that glaucoma shunt device causes either a breach in blood-aqueous barrier or chronic trauma, increasing influx of oxidative, apoptotic and inflammatory proteins that could potentially cause corneal endothelial damage.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Anshu A, Price MO, Richardson MR, et al. Alterations in the aqueous humor proteome in patients with a glaucoma shunt device. Mol Vis. 2011;17:1891-1900.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Molecular Vision
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}