First-trimester cervical length screening and the risk of preterm birth: a systematic review and meta-analysis

Date
2025-10-06
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
BioMed Central
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Background: The clinical utility of first-trimester cervical length (CL) measurement remains uncertain. This systematic review and meta-analysis aimed to evaluate the association between first-trimester CL measurement and preterm birth (PTB) risk.

Methods: This study was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in PROSPERO (CRD42023462610). A comprehensive search was conducted across four electronic databases (PubMed, Scopus, Web of Science, and Cochrane Library) until January 29, 2024, using MeSH terms and keywords. We included randomized controlled trials, comparative observational studies, and retrospective studies that examined first-trimester CL measurement and reported PTB as a primary or secondary outcome. Two independent reviewers conducted study selection and data extraction, resolving discrepancies through discussion. Risk of bias was assessed using the Newcastle-Ottawa Scale. A meta-analysis using a random-effects model was conducted, with heterogeneity evaluated via I² statistics.

Results: Five studies comprising 16,053 pregnancies were included. CL was significantly shorter in individuals delivering before 34 weeks compared to those delivering at or after 34 weeks, with a pooled mean difference of -0.59 mm (95% confidence interval [CI]: -1.14 to -0.04; p = 0.04; I²=72.56%). Similarly, those delivering before 37 weeks had a significantly shorter CL than those delivering at or after 37 weeks, with a pooled mean difference of -0.23 mm (95% CI: -0.43 to -0.03; p = 0.02; I²=76.26%).

Conclusion: First-trimester CL measurement is significantly associated with PTB risk. However, due to study heterogeneity and physiological variability in early pregnancy, its clinical utility as a predictive tool remains uncertain. Further research with standardized protocols and larger cohorts is needed to assess its role in screening and early intervention strategies for both low- and high-risk pregnancies.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Hantoushzadeh S, Saedi N, Jafarabady K, et al. First-trimester cervical length screening and the risk of preterm birth: a systematic review and meta-analysis. BMC Pregnancy Childbirth. 2025;25(1):1018. Published 2025 Oct 6. doi:10.1186/s12884-025-08210-x
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
BMC Pregnancy and Childbirth
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}