A Randomized, Controlled Study Comparing Two Standardized Closure Methods of Laparoscopic Port Sites

Date
2010
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Society of Laparoendoscopic Surgeons
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Objectives: To compare octyl-cyanoacrylate tissue adhesive (OCT) with the standard suture technique for the closure of laparoscopic port sites.

Methods: This was a randomized clinical trial of 40 patients. All participants had 2 lower abdominal ports, with one port closed using OCT while the opposite port was closed with 4-0 monocryl suture. An evaluation of the wound was performed 2 weeks to 4 weeks after surgery. The Hollander Wound Evaluation Scale (HWES, including step-off of borders, contour irregularities, margin separation, edge inversion, excessive distortion, and overall appearance) was used for cosmetic evaluation. Complications, such as erythema, warmth, tenderness, drainage, and wound infection, were evaluated. Analysis of complications was performed using the chi-square test, and cosmetic evaluation including individual components of the HWES was compared with the t test, P<0.05 considered significant.

Results: Eighty wounds were evaluated in 40 patients. The number of patients with complications including erythema (1/40 vs. 16/40), tenderness (1/40 vs. 19/40), and drainage (1/40 vs. 9/40) was lower with OCT than with sutures, respectively (all P<0.001). The ports closed with OCT had higher overall HWES, ie, better cosmetic score (5.92 ± 0.05 vs 5.50±0.13) and lower margin separation (1/40 vs. 10/40) but had higher contour irregularity (6/40 vs. 1/40) (all P=0.05). However, skin contour irregularity was significantly better when OCT was applied using fine tissue forceps (P=0.002).

Conclusion: Laparoscopic ports closed with OCT had fewer early complications, such as wound erythema, tenderness, and drainage. Ports closed with OCT had a better cosmetic appearance.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Chen K, Klapper AS, Voige H, Del Priore G. A randomized, controlled study comparing two standardized closure methods of laparoscopic port sites. JSLS. 2010;14(3):391-394. doi:10.4293/108680810X12924466006729
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
JSLS
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}