Diffusion tractography of kidney by high angular resolution diffusion imaging

Date
2024-03-24
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Diffusion magnetic resonance imaging (MRI) has been utilized to probe the renal microstructures but investigating the three-dimensional (3D) tubular network still presents significant challenges due to the complicated architecture of kidney. This study aims to assess whether high angular resolution diffusion imaging (HARDI) could improve the reconstruction of 3D tubular architectures. Kidneys from both mice and rats were imaged using 3D diffusion-weighted pulse sequences at 9.4 T. Five healthy mouse kidneys were scanned at an isotropic spatial resolution of 40 μm, with a b value of 1500 s/mm2 across 46 diffusion encoding directions. The study employed diffusion tensor imaging (DTI) and generalized Q-sampling imaging (GQI) to examine the tubular orientation distributions and tractography, validated by conventional histology. Fractional anisotropy (FA) and mean diffusivity (MD) were quantified and compared among the inner medullar (IM), outer medullar (OM), and cortex (CO) at different angular resolutions. FA values, estimated with 6 diffusion-weighted images (DWIs), were significantly overestimated by 49.9% (p < 0.001) in IM, 179.4% (p < 0.001) in OM, and 225.5% (p < 0.001) in CO, compared to using 46 DWIs. In contrast, MD exhibited less variations to angular resolution variations (3.4% in IM, 4.2% in OM, and 4.6% in CO). Both DTI and GQI at high angular resolution successfully traced renal tubular structures throughout the kidney, with GQI demonstrating superior performance in generating more continuous tracts. Furthermore, disrupted renal tubule structures were observed in a chronic kidney disease (CKD) rat model. HARDI, especially when combined with the GQI approach, holds promise in tracking complicated 3D tubule architectures and may serve as a potent tool for kidney disease research.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Maharjan S, Chen J, Gaughan A, Chen NX, Wang N. Diffusion tractography of kidney by high angular resolution diffusion imaging. Magn Reson Lett. 2024;4(4):200117. Published 2024 Mar 24. doi:10.1016/j.mrl.2024.200117
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Magnetic Resonance Letters
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}