Cortical bone mechanics technology signal quality maintains robustness across a range of biometric profiles

Date
2025-07-09
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Oxford University Press
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Current methods of diagnosing osteoporosis, such as DXA, have limitations in predicting fracture risk. Cortical bone mechanics technology (CBMT) offers a novel approach by using a three-point bend test with multifrequency vibration analysis to directly measure ulnar bending stiffness and calculate flexural rigidity, a mechanical property highly predictive of whole-bone strength under bending conditions. Cortical bone mechanics technology targets the diaphyseal ulna, a site composed primarily of cortical bone, enhancing its specificity for cortical bone quality. In this study of 388 postmenopausal women, we developed and validated a 20-point signal quality indicator (SQI) scoring system to quantify CBMT signal quality and evaluated its relationship to biometric characteristics. The SQI was developed through expert assessment of representative frequency response function (vibration data) trials and refined over 17 iterations. The final system achieved excellent classification performance (AUC = 0.974; sensitivity, specificity, and accuracy all >97%). A total of 22 740 trials were collected across 758 total arm tests, sampling 10 ulnar sites per arm under three vibration amplitudes. Two expert analysts evaluated signal features associated with high signal quality. The resulting SQI is fully automated and provides real-time feedback. All correlations between SQI scores and biometric attributes were weak or very weak (|ρ| < 0.30). The correlations with body weight (ρ = -0.11), BMI (ρ = -0.12), ulnar BMD (ρ = -0.17), CBMT-derived flexural rigidity (ρ = -0.28), and grip strength (ρ = 0.17) were statistically significant (p < .05) but remained small in magnitude. SQI scores were modestly lower in individuals with higher BMI or flexural rigidity (~2 to 3 points), but values remained in the acceptable-to-good range. This study introduces a robust, automated CBMT signal quality metric and demonstrates that its performance remains stable across a broad range of biometric profiles, supporting its application in both clinical and research settings.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Dick A, Stoeckel M, Ruzzenne M, et al. Cortical bone mechanics technology signal quality maintains robustness across a range of biometric profiles. JBMR Plus. 2025;9(9):ziaf116. Published 2025 Jul 9. doi:10.1093/jbmrpl/ziaf116
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
JBMR Plus
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}