Comparison of mass spectrometry and fourier transform infrared spectroscopy of plasma samples in identification of patients with fracture-related infections

Date
2025-09-22
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Public Library of Science
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Objectives: Fracture-related infections (FRIs) have significant impact on patient outcomes. Diagnosing FRIs is challenging due to lack of robust, minimally invasive diagnostic tests in the early stages of the disease. The objective of this study was to evaluate the ability of proteomic mass spectrometry (MS) (quantitative approach) and spectral pattern analysis based on fourier transform infrared (FTIR) spectroscopy of plasma samples (qualitative approach) in discriminating between FRI and controls.

Materials and methods: A prospective case-control study at a level 1 trauma center was conducted. Patients meeting confirmatory FRI criteria were matched with controls without infection based on age, time after surgery, and fracture region. Plasma samples were collected at the time of presentation for FRI and saved for batch analysis. Tandem mass tag liquid chromatography-mass spectrometry was used for proteomics, and FTIR spectroscopy of dried films was used to obtain mid-infrared spectra from samples. Mid-infrared spectra were preprocessed, and for MS data, protein abundance ratios of FRI and controls were compared. Multivariate analysis-based predictive models were developed separately for FTIR-based spectra and MS-based protein ratio data.

Results: Thirteen FRI and 13 controls were included in the study. The predictive models based on FTIR spectroscopy data had an average area under the receiver operating characteristic (AUROC) of ≈0.803, CI95(0.8, 0.81), the average sensitivity was ≈ 0. 0.755, CI95(0.75, 0.76), and the specificity was ≈ 0.677, CI95(0.672, 0.682). The MS-based predictive models from protein abundance ratio results had an average AUROC of ≈0.735, CI95(0.732, 0.737), the average sensitivity was ≈ 0.74, CI95 (0.739, 0.747), and the specificity was ≈ 0.653, CI95(0.649, 0.656).

Discussion and conclusions: Mass spectrometry and spectral pattern recognition based on FTIR spectroscopy can both be used to develop predictive models that can discriminate between FRI and control samples. There is potential for both analytical approaches as candidate diagnostic biomarkers in FRI patients that require further validation in future studies.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Malek S, Natoli RM, Rajwa B. Comparison of mass spectrometry and fourier transform infrared spectroscopy of plasma samples in identification of patients with fracture-related infections. PLoS One. 2025;20(9):e0330743. Published 2025 Sep 22. doi:10.1371/journal.pone.0330743
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
PLoS One
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}