Patterns of red blood cell utilization: Harnessing electronic health records data from the Information Standard for Blood and Transplant (ISBT) 128 system within the Biologics Effectiveness and Safety (BEST) initiative

Date
2024-06
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wiley
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Background Current hemovigilance methods generally rely on survey data or administrative claims data utilizing billing and revenue codes, each of which has limitations. We used electronic health records (EHR) linked to blood bank data to comprehensively characterize red blood cell (RBC) utilization patterns and trends in three healthcare systems participating in the U.S. Food and Drug Administration Center for Biologics Evaluation and Research Biologics Effectiveness and Safety (BEST) initiative.

Methods We used Information Standard for Blood and Transplant (ISBT) 128 codes linked to EHR from three healthcare systems data sources to identify and quantify RBC-transfused individuals, RBC transfusion episodes, transfused RBC units, and processing methods per year during 2012–2018.

Results There were 577,822 RBC units transfused among 112,705 patients comprising 345,373 transfusion episodes between 2012 and 2018. Utilization in terms of RBC units and patients increased slightly in one and decreased slightly in the other two healthcare facilities. About 90% of RBC-transfused patients had 1 (~46%) or 2–5 (~42%)transfusion episodes in 2018. Among the small proportion of patients with ≥12 transfusion episodes per year, approximately 60% of episodes included only one RBC unit. All facilities used leukocyte-reduced RBCs during the study period whereas irradiated RBC utilization patterns differed across facilities.

Discussion ISBT 128 codes and EHRs were used to observe patterns of RBC transfusion and modification methods at the unit level and patient level in three healthcare systems participating in the BEST initiative. This study shows that the ISBT 128 coding system in an EHR environment provides a feasible source for hemovigilance activities.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Obidi, J., Sridhar, G., Dores, G. M., Whitaker, B., Villa, C. H., Storch, E., Chada, K., Schilling, L. M., Natarajan, K., Biondich, P., Soares, A., Spotnitz, M., Falconer, T., Purkayastha, S., Draper, N. L., Wong, H.-L., Stagg, M., Reich, C., Anderson, S., & Shoaibi, A. (2024). Patterns of red blood cell utilization: Harnessing electronic health records data from the Information Standard for Blood and Transplant (ISBT) 128 system within the Biologics Effectiveness and Safety (BEST) initiative. Transfusion, 64(6), 998–1007. https://doi.org/10.1111/trf.17852
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Transfusion
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}