ScholarWorksIndianapolis
  • Communities & Collections
  • Browse ScholarWorks
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Xia, Zeyang"

Now showing 1 - 6 of 6
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Estimation of periodontal ligament’s equivalent mechanical parameters for finite element modeling
    (Elsevier, 2013) Xia, Zeyang; Jiang, Feifei; Chen, Jie; Mechanical and Energy Engineering, Purdue School of Engineering and Technology
    Introduction: Young's modulus (E) and Poisson's ratio (v) of the periodontal ligament are needed in a finite element analysis for investigating the biomechanical behavior of a tooth, periodontal ligament, and bone complex. However, large discrepancies in E (0.01-1,750 MPa) and v (0.28-0.49) were reported previously. The objective of this study was to narrow the ranges and to provide equivalent E and v pairs suitable for finite element modeling of a tooth, periodontal ligament, and bone complex by using a reported crown load-displacement relationship as the criterion. Methods: A 3-dimensional finite element model of a 3-tooth, periodontal ligament, and bone complex, consisting of a maxillary central incisor with 2 adjacent teeth, from a cone-beam computed tomography scan was created. The dimensions, constraints, and loading condition were kept similar to those reported in the human study. With the load applied to the crown, both v and E were adjusted independently, and the corresponding crown displacements were calculated. The resulting load-displacement curves were compared with those reported in the human study. The mean absolute displacement difference method was used to find the best fit. The E and v pairs that generated the minimum mean absolute displacement difference were identified. Results: The finite element model with 1 of the 3 E and v pairs (v = 0.35, E = 0.87 MPa; v = 0.4, E = 0.71 MPa; and v = 0.45, E = 0.47 MPa) simulated the tooth, periodontal ligament, and bone complex well. The mean absolute displacement differences were 0.0135, 0.0138, and 0.0138 mm, respectively; these are less than 8% of 0.175 mm, which was the crown displacement of the tooth, periodontal ligament, and bone complex under the load of 500 cN. Conclusions: The E and v values close to the 3 pairs might be used for finite element modeling of the tooth, periodontal ligament, and bone complex.
  • Loading...
    Thumbnail Image
    Item
    Hounsfield unit change in root and alveolar bone during canine retraction
    (Elsevier, 2015-04) Jiang, Feifei; Liu, Sean S.-Y.; Xia, Zeyang; Li, Shuning; Chen, Jie; Kula, Katherine S.; Eckert, George; Department of Orthodontics and Oral Facial Genetics, IU School of Dentistry
    INTRODUCTION: The objective of this study was to determine the Hounsfield unit (HU) changes in the alveolar bone and root surfaces during controlled canine retractions. METHODS: Eighteen maxillary canine retraction patients were selected for this split-mouth design clinical trial. The canines in each patient were randomly assigned to receive either translation or controlled tipping treatment. Pretreatment and posttreatment cone-beam computed tomography scans of each patient were used to determine tooth movement direction and HU changes. The alveolar bone and root surface were divided into 108 divisions, respectively. The HUs in each division were measured. Mixed-model analysis of variance was applied to test the HU change distribution at the P <0.05 significance level. RESULTS: The HU changes varied with the directions relative to the canine movement. The HU reductions occurred at the root surfaces. Larger reductions occurred in the divisions that were perpendicular to the moving direction. However, HUs decreased in the alveolar bone in the moving direction. The highest HU reduction was at the coronal level. CONCLUSIONS: HU reduction occurs on the root surface in the direction perpendicular to tooth movement and in the alveolar bone in the direction of tooth movement when a canine is retracted.
  • Loading...
    Thumbnail Image
    Item
    Load System of Segmental T-Loops for Canine Retraction
    (Elsevier, 2013) Xia, Zeyang; Chen, Jie; Jiang, Feifei; Li, Shuning; Viecilli, Rodrigo F.; Liu, Sean Y.; Orthodontics and Oral Facial Genetics, School of Dentistry
    Introduction: The orthodontic load system, especially ideal moment-to-force ratios, is the commonly used design parameter of segmental T-loops for canine retraction. However, the load system, including moment-to-force ratios, can be affected by the changes in canine angulations and interbracket distances. We hypothesized that clinical changes in canine position and angulation during canine retraction will significantly affect the load system delivered to the tooth. Methods: The load systems of 2 T-loop groups, one for translation and the other for controlled tipping, from 9 bilateral canine retraction patients were made to the targeted values obtained from finite element analyses and validated. Each loop was tested on the corresponding maxillary dental cast obtained in the clinic. The casts were made before and after each treatment interval so that both initial and residual load systems could be obtained. The pretreatment and posttreatment interbracket distances were recorded for calculating interbracket distance changes. Results: As the interbracket distances decreased, the average retraction-force drop per interbracket distance reduction was 36 cN/mm, a 30% drop per 1 mm of interbracket distance decrease. The average antitipping-moment drops per interbracket distance reductions were 0.02 N-mm per millimeter for controlled tipping and 1.4 N-mm per millimeter for translation, about 0.6% and 17% drops per 1 mm of interbracket decrease, respectively. Consequently, the average moment-to-force ratio increases per 1 mm of interbracket distance reduction were 1.24 mm per millimeter for controlled tipping and 6.34 mm per millimeter for translation. There was a significant residual load, which could continue to move the tooth if the patient missed the next-scheduled appointment. Conclusions: Clinical changes in canine position and angulation during canine retraction significantly affect the load system. The initial planned moment-to-force ratio needs to be lower to reach the expected average ideal value. Patients should be required to follow the office visit schedule closely to prevent negative effects because of significant moment-to-force ratios increases with time.
  • Loading...
    Thumbnail Image
    Item
    Three-dimensional canine displacement patterns in response to translation and controlled tipping retraction strategies
    (The Angle Orthodontist, 2015-01) Li, Shuning; Xia, Zeyang; Liu, Sean Shih-Yao; Eckert, George; Chen, Jie; Department of Mechanical Engineering, School of Engineering and Technology
    OBJECTIVE: To validate whether applying a well-defined initial three-dimensional (3D) load can create consistently expected tooth movement in patients. MATERIALS AND METHODS: Twenty-one patients who needed bilateral canine retraction to close extraction space were selected for this split-mouth clinical trial. After initial alignment and leveling, two canines in each patient were randomly assigned to receive either translation (TR) or controlled tipping (CT) load. The load was delivered by segmental T-loops designed to give specific initial moment/force ratios to the canines in each treatment interval (TI), verified with an orthodontic force tester. Maxillary dental casts were made before canine retraction and after each TI. The casts were digitized with a 3D laser scanner. The digital models were superimposed on the palatal rugae region. The 3D canine displacements and the displacement patterns in terms of TR, CT, and torque were calculated for each TI. RESULTS: The method can reliably detect a TR displacement greater than 0.3 mm and a rotation greater than 1.5°. Ninety-two TIs had displacements that were greater than 0.3 mm and were used for further analysis. Most displacements were oriented within ±45° from the distal direction. The displacement pattern in terms of TR or CT was not uniquely controlled by the initial moment/force ratio. CONCLUSIONS: The initial load system is not the only key factor controlling tooth movement. Using a segmental T-loop with a well-controlled load system, large variations in canine displacement can be expected clinically.
  • Loading...
    Thumbnail Image
    Item
    Three-dimensional quantification of pretorqued nickel-titanium wires in edgewise and prescription brackets
    (Allen Press, 2013) Mittal, Nitika; Xia, Zeyang; Chen, Jie; Stewart, Kelton T.; Liu, Sean Shih-Yao; Orthodontics and Oral Facial Genetics, School of Dentistry
    Objective: To quantify the three-dimensional moments and forces produced by pretorqued nickel-titanium (NiTi) rectangular archwires fully engaged in 0.018- and 0.022-inch slots of central incisor and molar edgewise and prescription brackets. Materials and methods: Ten identical acrylic dental models with retroclined maxillary incisors were fabricated for bonding with various bracket-wire combinations. Edgewise, Roth, and MBT brackets with 0.018- and 0.022-inch slots were bonded in a simulated 2 × 4 clinical scenario. The left central incisor and molar were sectioned and attached to load cells. Correspondingly sized straight and pretorqued NiTi archwires were ligated to the brackets using 0.010-inch ligatures. Each load cell simultaneously measured three force (Fx, Fy, Fz) and three moment (Mx, My, Mz) components. The faciolingual, mesiodistal, and inciso-occluso/apical axes of the teeth corresponded to the x, y, and z axes of the load cells, respectively. Each wire was removed and retested seven times. Three-way analysis of variance (ANOVA) examined the effects of wire type, wire size, and bracket type on the measured orthodontic load systems. Interactions among the three effects were examined and pair-wise comparisons between significant combinations were performed. Results: The force and moment components on each tooth were quantified according to their local coordinate axes. The three-way ANOVA interaction terms were significant for all force and moment measurements (P < .05), except for Fy (P > .05). Conclusion: The pretorqued wire generates a significantly larger incisor facial crown torquing moment in the MBT prescription compared to Roth, edgewise, and the straight NiTi wire.
  • Loading...
    Thumbnail Image
    Item
    Webots-based Simulator for Biped Navigation in Human-living Environments
    (IEEE, 2015-12) Xia, Zeyang; Wang, Xiaojun; Gan, Yangzhou; Cox, Thomas-Glyn Hunter; Zhang, Xue; Li, Huang; Xiong, Jing; Department of Biomedical Engineering, School of Engineering and Technology
    Navigation is one of the key issues of biped robot, especially in complicated and uncertain human-living environment. There have been challenges for ensuring the stability, efficiency and security of the biped navigation system. In this paper, a framework utilizing sampling-based footstep planner is proposed for the simulation of the biped navigation. Sensor fusion method is adopted to process and generate the correlated environment information for footstep planning. Two specific experiments have been conducted to validate the functionality and performance of the proposed framework.
About IU Indianapolis ScholarWorks
  • Accessibility
  • Privacy Notice
  • Copyright © 2025 The Trustees of Indiana University