- Browse by Author
Browsing by Author "Teunissen, Charlotte E."
Now showing 1 - 10 of 10
Results Per Page
Sort Options
Item Association of Plasma P-tau217 and P-tau181 with clinical phenotype, neuropathology, and imaging markers in Alzheimer’s disease and frontotemporal lobar degeneration: a retrospective diagnostic performance study(Elsevier, 2021) Thijssen, Elisabeth H.; La Joie, Renaud; Strom, Amelia; Fonseca, Corrina; Iaccarino, Leonardo; Wolf, Amy; Spina, Salvatore; Allen, Isabel E.; Cobigo, Yann; Heuer, Hilary; VandeVrede, Lawren; Proctor, Nicholas K.; Lago, Argentina Lario; Baker, Suzanne; Sivasankaran, Rajeev; Kieloch, Agnieszka; Kinhikar, Arvind; Yu, Lili; Valentin, Marie-Anne; Jeromin, Andreas; Zetterberg, Henrik; Hansson, Oskar; Mattsson-Carlgren, Niklas; Graham, Danielle; Blennow, Kaj; Kramer, Joel H.; Grinberg, Lea T.; Seeley, William W.; Rosen, Howard; Boeve, Bradley F.; Miller, Bruce L.; Teunissen, Charlotte E.; Rabinovici, Gil D.; Rojas, Julio C.; Dage, Jeffrey L.; Boxer, Adam L.; Advancing Research and Treatment for Frontotemporal Lobar Degeneration investigators; Neurology, School of MedicineBackground: Plasma tau phosphorylated at threonine 217 (p-tau217) and plasma tau phosphorylated at threonine 181 (p-tau181) are associated with Alzheimer's disease tau pathology. We compared the diagnostic value of both biomarkers in cognitively unimpaired participants and patients with a clinical diagnosis of mild cognitive impairment, Alzheimer's disease syndromes, or frontotemporal lobar degeneration (FTLD) syndromes. Methods: In this retrospective multicohort diagnostic performance study, we analysed plasma samples, obtained from patients aged 18-99 years old who had been diagnosed with Alzheimer's disease syndromes (Alzheimer's disease dementia, logopenic variant primary progressive aphasia, or posterior cortical atrophy), FTLD syndromes (corticobasal syndrome, progressive supranuclear palsy, behavioural variant frontotemporal dementia, non-fluent variant primary progressive aphasia, or semantic variant primary progressive aphasia), or mild cognitive impairment; the participants were from the University of California San Francisco (UCSF) Memory and Aging Center, San Francisco, CA, USA, and the Advancing Research and Treatment for Frontotemporal Lobar Degeneration Consortium (ARTFL; 17 sites in the USA and two in Canada). Participants from both cohorts were carefully characterised, including assessments of CSF p-tau181, amyloid-PET or tau-PET (or both), and clinical and cognitive evaluations. Plasma p-tau181 and p-tau217 were measured using electrochemiluminescence-based assays, which differed only in the biotinylated antibody epitope specificity. Receiver operating characteristic analyses were used to determine diagnostic accuracy of both plasma markers using clinical diagnosis, neuropathological findings, and amyloid-PET and tau-PET measures as gold standards. Difference between two area under the curve (AUC) analyses were tested with the Delong test. Findings: Data were collected from 593 participants (443 from UCSF and 150 from ARTFL, mean age 64 years [SD 13], 294 [50%] women) between July 1 and Nov 30, 2020. Plasma p-tau217 and p-tau181 were correlated (r=0·90, p<0·0001). Both p-tau217 and p-tau181 concentrations were increased in people with Alzheimer's disease syndromes (n=75, mean age 65 years [SD 10]) relative to cognitively unimpaired controls (n=118, mean age 61 years [SD 18]; AUC=0·98 [95% CI 0·95-1·00] for p-tau217, AUC=0·97 [0·94-0·99] for p-tau181; pdiff=0·31) and in pathology-confirmed Alzheimer's disease (n=15, mean age 73 years [SD 12]) versus pathologically confirmed FTLD (n=68, mean age 67 years [SD 8]; AUC=0·96 [0·92-1·00] for p-tau217, AUC=0·91 [0·82-1·00] for p-tau181; pdiff=0·22). P-tau217 outperformed p-tau181 in differentiating patients with Alzheimer's disease syndromes (n=75) from those with FTLD syndromes (n=274, mean age 67 years [SD 9]; AUC=0·93 [0·91-0·96] for p-tau217, AUC=0·91 [0·88-0·94] for p-tau181; pdiff=0·01). P-tau217 was a stronger indicator of amyloid-PET positivity (n=146, AUC=0·91 [0·88-0·94]) than was p-tau181 (n=214, AUC=0·89 [0·86-0·93]; pdiff=0·049). Tau-PET binding in the temporal cortex was more strongly associated with p-tau217 than p-tau181 (r=0·80 vs r=0·72; pdiff<0·0001, n=230). Interpretation: Both p-tau217 and p-tau181 had excellent diagnostic performance for differentiating patients with Alzheimer's disease syndromes from other neurodegenerative disorders. There was some evidence in favour of p-tau217 compared with p-tau181 for differential diagnosis of Alzheimer's disease syndromes versus FTLD syndromes, as an indication of amyloid-PET-positivity, and for stronger correlations with tau-PET signal. Pending replication in independent, diverse, and older cohorts, plasma p-tau217 and p-tau181 could be useful screening tools to identify individuals with underlying amyloid and Alzheimer's disease tau pathology.Item Axonal damage and inflammation response are biological correlates of decline in small-world values: a cohort study in autosomal dominant Alzheimer's disease(Oxford University Press, 2024-10-09) Vermunt, Lisa; Sutphen, Courtney L.; Dicks, Ellen; de Leeuw, Diederick M.; Allegri, Ricardo F.; Berman, Sarah B.; Cash, David M.; Chhatwal, Jasmeer P.; Cruchaga, Carlos; Day, Gregory S.; Ewers, Michael; Farlow, Martin R.; Fox, Nick C.; Ghetti, Bernardino; Graff-Radford, Neill R.; Hassenstab, Jason; Jucker, Mathias; Karch, Celeste M.; Kuhle, Jens; Laske, Christoph; Levin, Johannes; Masters, Colin L.; McDade, Eric; Mori, Hiroshi; Morris, John C.; Perrin, Richard J.; Preische, Oliver; Schofield, Peter R.; Suárez-Calvet, Marc; Xiong, Chengjie; Scheltens, Philip; Teunissen, Charlotte E.; Visser, Pieter Jelle; Bateman, Randall J.; Benzinger, Tammie L. S.; Fagan, Anne M.; Gordon, Brian A.; Tijms, Betty M.; Pathology and Laboratory Medicine, School of MedicineThe grey matter of the brain develops and declines in coordinated patterns during the lifespan. Such covariation patterns of grey matter structure can be quantified as grey matter networks, which can be measured with magnetic resonance imaging. In Alzheimer's disease, the global organization of grey matter networks becomes more random, which is captured by a decline in the small-world coefficient. Such decline in the small-world value has been robustly associated with cognitive decline across clinical stages of Alzheimer's disease. The biological mechanisms causing this decline in small-world values remain unknown. Cerebrospinal fluid (CSF) protein biomarkers are available for studying diverse pathological mechanisms in humans and can provide insight into decline. We investigated the relationships between 10 CSF proteins and small-world coefficient in mutation carriers (N = 219) and non-carriers (N = 136) of the Dominantly Inherited Alzheimer Network Observational study. Abnormalities in Amyloid beta, Tau, synaptic (Synaptosome associated protein-25, Neurogranin) and neuronal calcium-sensor protein (Visinin-like protein-1) preceded loss of small-world coefficient by several years, while increased levels in CSF markers for inflammation (Chitinase-3-like protein 1) and axonal injury (Neurofilament light) co-occurred with decreasing small-world values. This suggests that axonal loss and inflammation play a role in structural grey matter network changes.Item Characterization of pre-analytical sample handling effects on a panel of Alzheimer's disease–related blood-based biomarkers: Results from the Standardization of Alzheimer's Blood Biomarkers (SABB) working group(Wiley, 2022) Verberk, Inge M. W.; Misdorp, Els O.; Koelewijn, Jannet; Ball, Andrew J.; Blennow, Kaj; Dage, Jeffrey L.; Fandos, Noelia; Hansson, Oskar; Hirtz, Christophe; Janelidze, Shorena; Kang, Sungmin; Kirmess, Kristopher; Kindermans, Jana; Lee, Ryan; Meyer, Matthew R.; Shan, Dandan; Shaw, Leslie M.; Waligorska, Teresa; West, Tim; Zetterberg, Henrik; Edelmayer, Rebecca M.; Teunissen, Charlotte E.; Neurology, School of MedicineIntroduction: Pre-analytical sample handling might affect the results of Alzheimer's disease blood-based biomarkers. We empirically tested variations of common blood collection and handling procedures. Methods: We created sample sets that address the effect of blood collection tube type, and of ethylene diamine tetraacetic acid plasma delayed centrifugation, centrifugation temperature, aliquot volume, delayed storage, and freeze–thawing. We measured amyloid beta (Aβ)42 and 40 peptides with six assays, and Aβ oligomerization-tendency (OAβ), amyloid precursor protein (APP)699-711, glial fibrillary acidic protein (GFAP), neurofilament light (NfL), total tau (t-tau), and phosphorylated tau181. Results: Collection tube type resulted in different values of all assessed markers. Delayed plasma centrifugation and storage affected Aβ and t-tau; t-tau was additionally affected by centrifugation temperature. The other markers were resistant to handling variations. Discussion: We constructed a standardized operating procedure for plasma handling, to facilitate introduction of blood-based biomarkers into the research and clinical settings.Item Clinical and analytical comparison of six Simoa assays for plasma P-tau isoforms P-tau181, P-tau217, and P-tau231(BMC, 2021-12-04) Bayoumy, Sherif; Verberk, Inge M.W.; den Dulk, Ben; Hussainali, Zulaiga; Zwan, Marissa; van der Flier, Wiesje M.; Ashton, Nicholas J.; Zetterberg, Henrik; Blennow, Kaj; Vanbrabant, Jeroen; Stoops, Erik; Vanmechelen, Eugeen; Dage, Jeffrey L.; Teunissen, Charlotte E.; Neurology, School of MedicineIntroduction: Studies using different assays and technologies showed highly promising diagnostic value of plasma phosphorylated (P-)tau levels for Alzheimer's disease (AD). We aimed to compare six P-tau Simoa assays, including three P-tau181 (Eli Lilly, ADx, Quanterix), one P-tau217 (Eli Lilly), and two P-tau231 (ADx, Gothenburg). Methods: We studied the analytical (sensitivity, precision, parallelism, dilution linearity, and recovery) and clinical (40 AD dementia patients, age 66±8years, 50%F; 40 age- and sex-matched controls) performance of the assays. Results: All assays showed robust analytical performance, and particularly P-tau217 Eli Lilly; P-tau231 Gothenburg and all P-tau181 assays showed robust clinical performance to differentiate AD from controls, with AUCs 0.936-0.995 (P-tau231 ADx: AUC = 0.719). Results obtained with all P-tau181 assays, P-tau217 Eli Lilly assay, and P-tau231 Gothenburg assay strongly correlated (Spearman's rho > 0.86), while correlations with P-tau231 ADx results were moderate (rho < 0.65). Discussion: P-tau isoforms can be measured robustly by several novel high-sensitive Simoa assays.Item Detecting amyloid positivity in early Alzheimer’s disease using combinations of plasma Aβ42/Aβ40 and p-tau(Wiley, 2022-02) Janelidze, Shorena; Palmqvist, Sebastian; Leuzy, Antoine; Stomrud, Erik; Verberk, Inge M.W.; Zetterberg, Henrik; Ashton, Nicholas J.; Pesini, Pedro; Sarasa, Leticia; Allué, José Antonio; Teunissen, Charlotte E.; Dage, Jeffrey L.; Blennow, Kaj; Mattsson-Carlgren, Niklas; Hansson, Oskar; Neurology, School of MedicineIntroduction: We studied usefulness of combining blood amyloid beta (Aβ)42/Aβ40, phosphorylated tau (p-tau)217, and neurofilament light (NfL) to detect abnormal brain Aβ deposition in different stages of early Alzheimer's disease (AD). Methods: Plasma biomarkers were measured using mass spectrometry (Aβ42/Aβ40) and immunoassays (p-tau217 and NfL) in cognitively unimpaired individuals (CU, N = 591) and patients with mild cognitive impairment (MCI, N = 304) from two independent cohorts (BioFINDER-1, BioFINDER-2). Results: In CU, a combination of plasma Aβ42/Aβ40 and p-tau217 detected abnormal brain Aβ status with area under the curve (AUC) of 0.83 to 0.86. In MCI, the models including p-tau217 alone or Aβ42/Aβ40 and p-tau217 had similar AUCs (0.86-0.88); however, the latter showed improved model fit. The models were implemented in an online application providing individualized risk assessments (https://brainapps.shinyapps.io/PredictABplasma/). Discussion: A combination of plasma Aβ42/Aβ40 and p-tau217 discriminated Aβ status with relatively high accuracy, whereas p-tau217 showed strongest associations with Aβ pathology in MCI but not in CU.Item Head-to-head comparison between plasma p-tau217 and flortaucipir-PET in amyloid-positive patients with cognitive impairment(BMC, 2023-09-22) Mundada, Nidhi S.; Rojas, Julio C.; Vandevrede, Lawren; Thijssen, Elisabeth H.; Iaccarino, Leonardo; Okoye, Obiora C.; Shankar, Ranjani; Soleimani‑Meigooni, David N.; Lago, Argentina L.; Miller, Bruce L.; Teunissen, Charlotte E.; Heuer, Hillary; Rosen, Howie J.; Dage, Jeffrey L.; Jagust, William J.; Rabinovici, Gil D.; Boxer, Adam L.; La Joie, Renaud; Neurology, School of MedicineBackground: Plasma phosphorylated tau (p-tau) has emerged as a promising biomarker for Alzheimer's disease (AD). Studies have reported strong associations between p-tau and tau-PET that are mainly driven by differences between amyloid-positive and amyloid-negative patients. However, the relationship between p-tau and tau-PET is less characterized within cognitively impaired patients with a biomarker-supported diagnosis of AD. We conducted a head-to-head comparison between plasma p-tau217 and tau-PET in patients at the clinical stage of AD and further assessed their relationships with demographic, clinical, and biomarker variables. Methods: We retrospectively included 87 amyloid-positive patients diagnosed with MCI or dementia due to AD who underwent structural MRI, amyloid-PET (11C-PIB), tau-PET (18F-flortaucipir, FTP), and blood draw assessments within 1 year (age = 66 ± 10, 48% female). Amyloid-PET was quantified in Centiloids (CL) while cortical tau-PET binding was measured using standardized uptake value ratios (SUVRs) referenced against inferior cerebellar cortex. Plasma p-tau217 concentrations were measured using an electrochemiluminescence-based assay on the Meso Scale Discovery platform. MRI-derived cortical volume was quantified with FreeSurfer. Mini-Mental State Examination (MMSE) scores were available at baseline (n = 85) and follow-up visits (n = 28; 1.5 ± 0.7 years). Results: Plasma p-tau217 and cortical FTP-SUVR were correlated (r = 0.61, p < .001), especially in temporo-parietal and dorsolateral frontal cortices. Both higher p-tau217 and FTP-SUVR values were associated with younger age, female sex, and lower cortical volume, but not with APOE-ε4 carriership. PIB-PET Centiloids were weakly correlated with FTP-SUVR (r = 0.26, p = 0.02), but not with p-tau217 (r = 0.10, p = 0.36). Regional PET-plasma associations varied with amyloid burden, with p-tau217 being more strongly associated with tau-PET in temporal cortex among patients with moderate amyloid-PET burden, and with tau-PET in primary cortices among patients with high amyloid-PET burden. Higher p-tau217 and FTP-SUVR values were independently associated with lower MMSE scores cross-sectionally, while only baseline FTP-SUVR predicted longitudinal MMSE decline when both biomarkers were included in the same model. Conclusion: Plasma p-tau217 and tau-PET are strongly correlated in amyloid-PET-positive patients with MCI or dementia due to AD, and they exhibited comparable patterns of associations with demographic variables and with markers of downstream neurodegeneration.Item Novel avenues of tau research(Wiley, 2024) Sexton, Claire E.; Bitan, Gal; Bowles, Kathryn R.; Brys, Miroslaw; Buée, Luc; Bukar Maina, Mahmoud; Clelland, Claire D.; Cohen, Ann D.; Crary, John F.; Dage, Jeffrey L.; Diaz, Kristophe; Frost, Bess; Gan, Li; Goate, Alison M.; Golbe, Lawrence I.; Hansson, Oskar; Karch, Celeste M.; Kolb, Hartmuth C.; La Joie, Renaud; Lee, Suzee E.; Matallana, Diana; Miller, Bruce L.; Onyike, Chiadi U.; Quiroz, Yakeel T.; Rexach, Jessica E.; Rohrer, Jonathan D.; Rommel, Amy; Sadri-Vakili, Ghazaleh; Schindler, Suzanne E.; Schneider, Julie A.; Sperling, Reisa A.; Teunissen, Charlotte E.; Weninger, Stacie C.; Worley, Susan L.; Zheng, Hui; Carrillo, Maria C.; Neurology, School of MedicineIntroduction: The pace of innovation has accelerated in virtually every area of tau research in just the past few years. Methods: In February 2022, leading international tau experts convened to share selected highlights of this work during Tau 2022, the second international tau conference co-organized and co-sponsored by the Alzheimer's Association, CurePSP, and the Rainwater Charitable Foundation. Results: Representing academia, industry, and the philanthropic sector, presenters joined more than 1700 registered attendees from 59 countries, spanning six continents, to share recent advances and exciting new directions in tau research. Discussion: The virtual meeting provided an opportunity to foster cross-sector collaboration and partnerships as well as a forum for updating colleagues on research-advancing tools and programs that are steadily moving the field forward.Item Plasma biomarkers predict amyloid pathology in cognitively normal monozygotic twins after 10 years(Oxford University Press, 2023-02-04) den Braber, Anouk; Verberk, Inge M. W.; Tomassen, Jori; den Dulk, Ben; Stoops, Erik; Dage, Jeffrey L.; Collij, Lyduine E.; Barkhof, Frederik; Willemsen, Gonneke; Nivard, Michel G.; van Berckel, Bart N. M.; Scheltens, Philip; Visser, Pieter Jelle; de Geus, Eco J. C.; Teunissen, Charlotte E.; Neurology, School of MedicineBlood-based biomarkers could prove useful to predict Alzheimer's disease core pathologies in advance of clinical symptoms. Implementation of such biomarkers requires a solid understanding of their long-term dynamics and the contribution of confounding to their association with Alzheimer's disease pathology. Here we assess the value of plasma amyloid-β1-42/1-40, phosphorylated-tau181 and glial fibrillary acidic protein to detect early Alzheimer's disease pathology, accounting for confounding by genetic and early environmental factors. Participants were 200 monozygotic twins, aged ≥60 years with normal cognition from the european medical information framework for Alzheimer's disease study. All twins had amyloid-β status and plasma samples available at study enrolment. For 80 twins, additional plasma samples were available that had been collected approximately 10 years prior to amyloid-β status assessment. Single-molecule array assays were applied to measure amyloid-β1-42/1-40, phosphorylated-tau181 and glial fibrillary acidic protein. Predictive value of and longitudinal change in these biomarkers were assessed using receiver operating characteristic curve analysis and linear mixed models. Amyloid pathology could be predicted using blood-based biomarkers obtained at the time of amyloid status assessment (amyloid-β1-42/1-40: area under the curve = 0.65, P = 0.01; phosphorylated-tau181: area under the curve = 0.84, P < 0.001; glial fibrillary acidic protein: area under the curve = 0.74, P < 0.001), as well as using those obtained 10 years prior to amyloid status assessment (amyloid-β1-42/1-40: area under the curve = 0.69, P = 0.03; phosphorylated-tau181: area under the curve = 0.92, P < 0.001; glial fibrillary acidic protein: area under the curve = 0.84, P < 0.001). Longitudinally, amyloid-β1-42/1-40 levels decreased [β (SE) = -0.12 (0.01), P < 0.001] and phosphorylated-tau181 levels increased [β (SE) = 0.02 (0.01), P = 0.004]. Amyloid-β-positive individuals showed a steeper increase in phosphorylated-tau181 compared with amyloid-β-negative individuals [β (SE) = 0.06 (0.02), P = 0.004]. Also amyloid-β-positive individuals tended to show a steeper increase in glial fibrillary acidic protein [β (SE) = 0.04 (0.02), P = 0.07]. Within monozygotic twin pairs, those with higher plasma phosphorylated-tau181 and lower amyloid-β1-42/1-40 levels were more likely to be amyloid-β positive [β (SE) = 0.95 (0.26), P < 0.001; β (SE) = -0.28 (0.14), P < 0.05] indicating minimal contribution of confounding by genetic and early environmental factors. Our data support the use of amyloid-β1-42/1-40, phosphorylated-tau181 and glial fibrillary acidic protein as screening tools for Alzheimer's disease pathology in the normal aging population, which is of importance for enrolment of high-risk subjects in secondary, or even primary, prevention trials. Furthermore, these markers show potential as low-invasive monitoring tool of disease progression and possibly treatment effects in clinical trials.Item The CentiMarker Project: Standardizing Quantitative Alzheimer’s disease Fluid Biomarkers for Biologic Interpretation(medRxiv, 2024-07-27) Wang, Guoqiao; Li, Yan; Xiong, Chengjie; Cao, Yuchen; Schindler, Suzanne E.; McDade, Eric; Blennow, Kaj; Hansson, Oskar; Dage, Jeffrey L.; Jack, Clifford R., Jr.; Teunissen, Charlotte E.; Shaw, Leslie M.; Zetterberg, Henrik; Ibanez, Laura; Timsina, Jigyasha; Carlos, Cruchaga; DIAN-TU Study Team; Bateman, Randall J.; Neurology, School of MedicineIntroduction: Biomarkers have been essential to understanding Alzheimer's disease (AD) pathogenesis, pathophysiology, progression, and treatment effects. However, each biomarker measure is a representation of the biological target, the assay used to measure it, and the variance of the assay. Thus, biomarker measures are difficult to compare without standardization, and the units and magnitude of effect relative to the disease are difficult to appreciate, even for experts. To facilitate quantitative comparisons of AD biomarkers in the context of biologic and treatment effects, we propose a biomarker standardization approach between normal ranges and maximum abnormal AD ranges, which we refer to as CentiMarker, similar to the Centiloid approach used in PET. Methods: We developed a standardization scale that creates percentile values ranging from 0 for a normal population to 100 for the most abnormal measures across disease stages. We applied this scale to CSF and plasma biomarkers in autosomal dominant AD, assessing the distribution by estimated years from symptom onset, between biomarkers, and across cohorts. We then validated this approach in a large national sporadic AD cohort. Results: We found the CentiMarker scale provided an easily interpretable metric of disease abnormality. The biologic changes, range, and distribution of several AD fluid biomarkers including amyloid-β, phospho-tau and other biomarkers, were comparable across disease stages in both early onset autosomal dominant and sporadic late onset AD. Discussion: The CentiMarker scale offers a robust and versatile framework for the standardized biological comparison of AD biomarkers. Its broader adoption could facilitate biomarker reporting, allowing for more informed cross-study comparisons and contributing to accelerated therapeutic development.Item The global Alzheimer's Association round robin study on plasma amyloid β methods(Wiley, 2021-10-14) Pannee, Josef; Shaw, Leslie M.; Korecka, Magdalena; Waligorska, Teresa; Teunissen, Charlotte E.; Stoops, Erik; Vanderstichele, Hugo M. J.; Mauroo, Kimberley; Verberk, Inge M. W.; Keshavan, Ashvini; Pesini, Pedro; Sarasa, Leticia; Pascual-Lucas, Maria; Fandos, Noelia; Allué, José-Antonio; Portelius, Erik; Andreasson, Ulf; Yoda, Ritsuko; Nakamura, Akinori; Kaneko, Naoki; Yang, Shieh-Yueh; Liu, Huei-Chun; Palme, Stefan; Bittner, Tobias; Mawuenyega, Kwasi G.; Ovod, Vitaliy; Bollinger, James; Bateman, Randall J.; Li, Yan; Dage, Jeffrey L.; Stomrud, Erik; Hansson, Oskar; Schott, Jonathan M.; Blennow, Kaj; Zetterberg, Henrik; Neurology, School of MedicineIntroduction: Blood-based assays to measure brain amyloid beta (Aβ) deposition are an attractive alternative to the cerebrospinal fluid (CSF)-based assays currently used in clinical settings. In this study, we examined different blood-based assays to measure Aβ and how they compare among centers and assays. Methods: Aliquots from 81 plasma samples were distributed to 10 participating centers. Seven immunological assays and four mass-spectrometric methods were used to measure plasma Aβ concentrations. Results: Correlations were weak for Aβ42 while Aβ40 correlations were stronger. The ratio Aβ42/Aβ40 did not improve the correlations and showed weak correlations. Discussion: The poor correlations for Aβ42 in plasma might have several potential explanations, such as the high levels of plasma proteins (compared to CSF), sensitivity to pre-analytical sample handling and specificity, and cross-reactivity of different antibodies. Different methods might also measure different pools of plasma Aβ42. We, however, hypothesize that greater correlations might be seen in future studies because many of the methods have been refined during completion of this study.