- Browse by Author
Browsing by Author "Kanapka, Lauren"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
Item Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trial.(Elsevier, 2022-04) Ware, Julia; Boughton, Charlotte K.; Allen, Janet M.; Wilinska, Malgorzata E.; Tauschmann, Martin; Denvir, Louise; Thankamony, Ajay; Campbell, Fiona M.; Wadwa, R. Paul; Buckingham, Bruce A.; Davis, Nikki; DiMeglio, Linda A.; Mauras, Nelly; Besser, Rachel E. J.; Ghatak, Atrayee; Weinzimer, Stuart A.; Hood, Korey K.; Fox, D. Steven; Kanapka, Lauren; Kollman, Craig; Sibayan, Judy; Beck, Roy W.; Hovorka, Roman; Pediatrics, School of MedicineBackground Closed-loop insulin delivery systems have the potential to address suboptimal glucose control in children and adolescents with type 1 diabetes. We compared safety and efficacy of the Cambridge hybrid closed-loop algorithm with usual care over 6 months in this population. Methods In a multicentre, multinational, parallel randomised controlled trial, participants aged 6–18 years using insulin pump therapy were recruited at seven UK and five US paediatric diabetes centres. Key inclusion criteria were diagnosis of type 1 diabetes for at least 12 months, insulin pump therapy for at least 3 months, and screening HbA1c levels between 53 and 86 mmol/mol (7·0–10·0%). Using block randomisation and central randomisation software, we randomly assigned participants to either closed-loop insulin delivery (closed-loop group) or to usual care with insulin pump therapy (control group) for 6 months. Randomisation was stratified at each centre by local baseline HbA1c. The Cambridge closed-loop algorithm running on a smartphone was used with either (1) a modified Medtronic 640G pump, Medtronic Guardian 3 sensor, and Medtronic prototype phone enclosure (FlorenceM configuration), or (2) a Sooil Dana RS pump and Dexcom G6 sensor (CamAPS FX configuration). The primary endpoint was change in HbA1c at 6 months combining data from both configurations. The primary analysis was done in all randomised patients (intention to treat). Trial registration ClinicalTrials.gov, NCT02925299. Findings Of 147 people initially screened, 133 participants (mean age 13·0 years [SD 2·8]; 57% female, 43% male) were randomly assigned to either the closed-loop group (n=65) or the control group (n=68). Mean baseline HbA1c was 8·2% (SD 0·7) in the closed-loop group and 8·3% (0·7) in the control group. At 6 months, HbA1c was lower in the closed-loop group than in the control group (between-group difference −3·5 mmol/mol (95% CI −6·5 to −0·5 [–0·32 percentage points, −0·59 to −0·04]; p=0·023). Closed-loop usage was low with FlorenceM due to failing phone enclosures (median 40% [IQR 26–53]), but consistently high with CamAPS FX (93% [88–96]), impacting efficacy. A total of 155 adverse events occurred after randomisation (67 in the closed-loop group, 88 in the control group), including seven severe hypoglycaemia events (four in the closed-loop group, three in the control group), two diabetic ketoacidosis events (both in the closed-loop group), and two non-treatment-related serious adverse events. There were 23 reportable hyperglycaemia events (11 in the closed-loop group, 12 in the control group), which did not meet criteria for diabetic ketoacidosis. Interpretation The Cambridge hybrid closed-loop algorithm had an acceptable safety profile, and improved glycaemic control in children and adolescents with type 1 diabetes. To ensure optimal efficacy of the closed-loop system, usage needs to be consistently high, as demonstrated with CamAPS FX.Item Cost-Effectiveness of Closed-Loop Automated Insulin Delivery Using the Cambridge Hybrid Algorithm in Children and Adolescents with Type 1 Diabetes: Results from a Multicenter 6-Month Randomized Trial(Sage, 2024-03-17) Fox, D. Steven; Ware, Julia; Boughton, Charlotte K.; Allen, Janet M.; Wilinska, Malgorzata E.; Tauschmann, Martin; Denvir, Louise; Thankamony, Ajay; Campbell, Fiona; Wadwa, R. Paul; Buckingham, Bruce A.; Davis, Nikki; DiMeglio, Linda A.; Mauras, Nelly; Besser, Rachel E. J.; Ghatak, Atrayee; Weinzimer, Stuart A.; Kanapka, Lauren; Kollman, Craig; Sibayan, Judy; Beck, Roy W.; Hood, Korey K.; Hovorka, Roman; DAN05 Consortium; Pediatrics, School of MedicineBackground/objective: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). Methods: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. Results: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). Conclusions: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).Item Development and delivery of a brief family behavioral intervention to support continuous glucose monitor use in young children with type 1 diabetes(Wiley, 2022) Hilliard, Marisa E.; Commissariat, Persis V.; Kanapka, Lauren; Laffel, Lori M.; Levy, Wendy; Harrington, Kara; Anderson, Barbara J.; Miller, Kellee M.; DiMeglio, Linda A.; Pediatrics, School of MedicineBackground: Despite potential glycemic benefits of continuous glucose monitor (CGM) use in young children with type 1 diabetes, psychosocial and behavioral challenges may interfere with sustained use. We developed a 5-session family behavioral intervention (FBI) to support CGM use. Objective: We report on the multi-step development of the FBI, training interventionists, implementation in a 14-site clinical trial, and participant satisfaction. Methods: A multidisciplinary team created the FBI based on mixed-methods (i.e., survey data, qualitative research) preliminary work with parents of young children. Investigators trained non-physician staff to deliver the 5 sessions per an intervention manual. Trial participants received the FBI either during the first (FBI group, n = 50) or second 6-months (Crossover group, n = 44) of the 1-year trial. Investigators listened to session recordings to rate intervention fidelity, and participants rated satisfaction with the FBI. Results: The complete 5-session FBI was delivered to 89% of participants, in-person (73%) or by telephone (23%). Sessions lasted 23 min on average, and fidelity was high across sessions. Over 80% of participants rated very high satisfaction with all aspects of the FBI and offered few recommendations for improvement. Conclusions: Having been developed based on experiences and input of families of young children with type 1 diabetes, the FBI represented a novel behavioral approach to enhance sustained CGM use during a challenging developmental period. Evidence of strong feasibility and acceptability supports its potential for implementation in research and clinical care. As diabetes technologies evolve, the FBI may continue to be refined to address parents' most relevant concerns.Item Lived experience of CamAPS FX closed loop system in youth with type 1 diabetes and their parents(Wiley, 2022) Hood, Korey K.; Garcia-Willingham, Natasha; Hanes, Sarah; Tanenbaum, Molly L.; Ware, Julia; Boughton, Charlotte K.; Allen, Janet M.; Wilinska, Malgorzata E.; Tauschmann, Martin; Denvir, Louise; Thankamony, Ajay; Campbell, Fiona; Wadwa, R. Paul; Buckingham, Bruce A.; Davis, Nikki; DiMeglio, Linda A.; Mauras, Nelly; Besser, Rachel E. J.; Ghatak, Atrayee; Weinzimer, Stuart A.; Fox, D. Steven; Kanapka, Lauren; Kollman, Craig; Sibayan, Judy; Beck, Roy W.; Hovorka, Roman; DAN05 ConsortiumAim: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. Materials and methods: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. Results: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. Conclusions: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.