Sosa-Valencia, LeonardoHuppertz, JerômeWanert, FanélieHaberzetser, FrancoisSwanström, LeeMangiavillano, BenedettoEisendrath, PierreDeprez, PierreRobles-Medranda, CarlosCarrara, SilviaAl-Haddad, Mohammad A.Vilmann, PeterKoch, StephaneLarghi, AlbertoKhashab, Mouen2023-06-222023-06-222022Sosa-Valencia L, Huppertz J, Wanert F, et al. Design and validation of a therapeutic EUS training program using a live animal model: Taking training to the next level. Endosc Ultrasound. 2022;11(2):112-121. doi:10.4103/EUS-D-21-00124https://hdl.handle.net/1805/33922Background and objectives: EUS has evolved into a therapeutic modality for gastrointestinal disorders. Simulators, ex vivo models, and phantoms are the current teaching methods for therapeutic EUS (TEUS). We create and evaluate a high-fidelity simulated live animal model (HiFi SAM) for teaching endoscopists TEUS. Materials and methods: Designing a curriculum that uses HiFi SAM and enables trainees to perform realistic procedures with expert mentors. Results: Twenty-seven trainees participated in a 3-day program with 6 h of theoretical and 14 h of hands using life HiFi SAM. Eighteen experts participated. Twenty-two (20-25) TEUS were defined for each HiFi SAM, and 616 were performed in all. Of 616/264 (43%) were evaluated with a mean of 88 per course (ranging between 80 and 95). Ninety-one percent (240/264) of the procedures were completed successfully. In 24, success was not achieved due to technical and/or model problems. Student rating of HiFi SAM was: 71% excellent rating (scale 8-10) and 95% excellent/good. The HiFi SAM procedure evaluation was (scale 1-5): fine-needle biopsy: 4.79, radiofrequency: 4.76, common bile duct and gallbladder drainage: 4.75, cystic drainages: 4.72, neurolysis: 4.55, microbiopsy: 4.50, and hepatogastric drainage: 4.04, with an overall satisfaction rate of 4.56 (91%). A short survey showed: 83% would recommend absolutely (17% most likely), 33% think that ITEC training was sufficient for their practice, and 66% would like additional training, especially more practice in specific techniques rather than more clinical case discussion. Regarding impact on their practice, 66% of the trainees started a new procedure and/or noted improvement in previous ones. Conclusion: HiFi SAM is a complex model; however, experts and trainees are satisfied with the training this new curriculum provided.en-USAttribution-NonCommercial-ShareAlike 4.0 InternationalEducationFine-needle biopsyRadiofrequencyTeachingTrainingDesign and validation of a therapeutic EUS training program using a live animal model: Taking training to the next levelArticle