DeWitt, JohnCho, Chang-MinLin, JingmeiAl-Haddad, MohammadCanto, Marcia IreneSalamone, AshleyHruban, Ralph H.Messallam, Ahmed A.Khashab, Mouen A.2016-10-202016-10-202015-10DeWitt, J., Cho, C.-M., Lin, J., Al-Haddad, M., Canto, M. I., Salamone, A., … Khashab, M. A. (2015). Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study. Endoscopy International Open, 3(5), E471–E478. http://doi.org/10.1055/s-0034-13922222364-3722https://hdl.handle.net/1805/11211BACKGROUND AND STUDY AIMS: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United States) to a conventional 19-gauge Tru-Cut biopsy (EUS-TCB) needle (19G, Quick-Core, Cook Medical Inc.). PATIENTS AND METHODS: Patients referred for EUS who require possible histologic biopsy were prospectively randomized to EUS-FNB or EUS-TCB. With the initial needle, ≤ 3 biopsies were obtained until either technical failure or an adequate core was obtained. Patients with suspected inadequate biopsies were crossed over to the other needle and similarly ≤ 3 passes were obtained until adequate cores or technical failure occurred. Technical success, diagnostic histology, accuracy and complication rates were evaluated. RESULTS: Eighty-five patients (mean 58 years; 43 male) were randomized to FNB (n = 44) and TCB (n = 41) with seven patients excluded. Procedure indication, biopsy site, mass size, number of passes, puncture site, overall technical success and adverse events were similar between the two groups. FNB specimens had a higher prevalence of diagnostic histology (85 % vs. 57 %; P = 0.006), accuracy (88 % vs. 62 %; P = 0.02), mean total length (19.4 vs. 4.3 mm; P = 0.001), mean complete portal triads from liver biopsies (10.4 vs. 1.3; P = 0.0004) and required fewer crossover biopsies compared to those of TCB (2 % vs. 65 %; P = 0.0001). Overall technical success and complication rates were comparable. CONCLUSION: EUS-FNB using a 19-gauge FNB needle is superior to 19-gauge EUS-TCB needle.en-USAttribution-NonCommercial-NoDerivs 3.0 United StatesBiopsy, Fine-NeedleEndoscopic Ultrasound-Guided Fine Needle AspirationHistology NeedleBiopsy NeedleComparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded studyArticle