Taylor, Gregory M.Evans, DanielDoggette, Robert P.Wallace, Ryan C.Flack, Andrew T.Kennedy, Sarah K.2022-12-142022-12-142021-06-18Taylor GM, Evans D, Doggette RP, Wallace RC, Flack AT, Kennedy SK. Painless loss of vision: rapid diagnosis of a central retinal artery occlusion utilizing point-of-care ultrasound. Oxf Med Case Reports. 2021;2021(6):omab038. Published 2021 Jun 18. doi:10.1093/omcr/omab038https://hdl.handle.net/1805/30730Point-of-care ultrasound (POCUS) has become an essential part of the evaluation of vision loss among emergency physicians in the emergency department (ED). It is frequently used to evaluate for vitreous hemorrhage, foreign bodies, retinal detachment, optic neuritis and posterior vitreous detachment; however, it can also be used to evaluate for a central retinal artery occlusion (CRAO). A POCUS can reveal a hyperechoic density in the optic nerve sheath just proximal to the retinal surface, and this is referred to as a retrobulbar 'spot sign' (RBSS). We present the case of an 88-year-old male that presented to our community ED with a painless loss of vision to his right eye. A POCUS revealed an RBSS of the central retinal artery and he was subsequently diagnosed with a CRAO. At his 1-month follow-up, he has regained light perception and 15% of his vision, however, remains with significant visual impairment.en-USAttribution-NonCommercial 4.0 InternationalPoint-of-care ultrasoundEvaluation of vision lossRetinal surfacesPainless loss of vision: rapid diagnosis of a central retinal artery occlusion utilizing point-of-care ultrasoundArticle