Hou, Peter C.Filbin, Michael R.Napoli, AnthonyFeldman, JosephPang, Peter S.Sankoff, JeffreyLo, Bruce M.Dickey-White, HowardBirkhahn, Robert H.Shapiro, Nathan I.2017-06-052017-06-052016-08Hou, P. C., Filbin, M. R., Napoli, A., Feldman, J., Pang, P. S., Sankoff, J., … Shapiro, N. I. (2016). Cardiac Output Monitoring Managing Intravenous Therapy (COMMIT) to Treat Emergency Department Patients with Sepsis. Shock (Augusta, Ga.), 46(2), 132–138. http://doi.org/10.1097/SHK.0000000000000564https://hdl.handle.net/1805/12847OBJECTIVE: Fluid responsiveness is proposed as a physiology-based method to titrate fluid therapy based on preload dependence. The objectives of this study were to determine if a fluid responsiveness protocol would decrease progression of organ dysfunction, and a fluid responsiveness protocol would facilitate a more aggressive resuscitation. METHODS: Prospective, 10-center, randomized interventional trial. INCLUSION CRITERIA: suspected sepsis and lactate 2.0 to 4.0 mmol/L. Exclusion criteria (abbreviated): systolic blood pressure more than 90 mmHg, and contraindication to aggressive fluid resuscitation. INTERVENTION: fluid responsiveness protocol using Non-Invasive Cardiac Output Monitor (NICOM) to assess for fluid responsiveness (>10% increase in stroke volume in response to 5 mL/kg fluid bolus) with balance of a liter given in responsive patients. CONTROL: standard clinical care. OUTCOMES: primary-change in Sepsis-related Organ Failure Assessment (SOFA) score at least 1 over 72 h; secondary-fluids administered. Trial was initially powered at 600 patients, but stopped early due to a change in sponsor's funding priorities. RESULTS: Sixty-four patients were enrolled with 32 in the treatment arm. There were no significant differences between arms in age, comorbidities, baseline vital signs, or SOFA scores (P > 0.05 for all). Comparing treatment versus Standard of Care-there was no difference in proportion of increase in SOFA score of at least 1 point (30% vs. 33%) (note bene underpowered, P = 1.0) or mean preprotocol fluids 1,050 mL (95% confidence interval [CI]: 786-1,314) vs. 1,031 mL (95% CI: 741-1,325) (P = 0.93); however, treatment patients received more fluids during the protocol (2,633 mL [95% CI: 2,264-3,001] vs. 1,002 mL [95% CI: 707-1,298]) (P < 0.001). CONCLUSIONS: In this study of a "preshock" population, there was no change in progression of organ dysfunction with a fluid responsiveness protocol. A noninvasive fluid responsiveness protocol did facilitate delivery of an increased volume of fluid. Additional properly powered and enrolled outcomes studies are needed.en-USAttribution-NonCommercial-NoDerivs 3.0 United StatesFluid resuscitationSepsisShockStroke volumeVolume responsivenessCardiac Output Monitoring Managing Intravenous Therapy (COMMIT) to Treat Emergency Department Patients with SepsisArticle